![oxycom CABIN 400 Operating Manual Download Page 24](http://html.mh-extra.com/html/oxycom/cabin-400/cabin-400_operating-manual_1665220024.webp)
00010605 B
24
6 T
E C H N I C A L
S P E C I F I C A T I O N S
6.1
Technical details
Note
All specifications are indicative only and subject to change without
notice.
6.2
Water quality
The CABIN 400 requires the use of drinking water only. The use of dirty water or water
from pools or lakes is forbidden. If in doubt about water quality, ask the camping site
manager or the local water authority if the water supply meets the following
specifications. The table shows the parameters of the drinking water guidelines that
apply to the CABIN 400.
Table 2
CABIN 400 technical details
Power consumption
max. 240 W
Weight
approx. 24kg
12 V power supply requirement
approx. 4 A. (only when the pump
motor is running)
Maximum air flow
400 m
3
per hour
OXYZONE circuit board fuse
Glass fuse 5x20, 2 A., slow blow
Water reservoir connection box fuse
Fuse ATO, 5 A., slow blow
Table 3
Water quality required for the CABIN 400
Parameter
Max. value
Unit
Note
Chloride
150
mg/l
Annual average
Conductivity (20ºC)
125
mS/m
Total hardness
18
°D
mmol Ca
2+
plus Mg
2+