00010605 B
22
5 S
T O R A G E
M O D E
5.1
When
The CABIN 400 should be set to storage mode, if you do not intend to use it for four
weeks or more.
Why
The storage mode helps prevent chemical and bacteriological contamination of the
water reservoir and the OXYCELL in the roof unit.
5.2
Function
Step 1
Clean the inside of the unit as indicated on the instructions label of the bottle of
additive 2 (Bakterizid). First drain the water reservoir fully and refill it with fresh water.
Only then should you add additive 2 to the water reservoir.
Note
When the “storage mode” has been activated, the water reservoir will
no longer be automatically replenished. Water has to be poured into
the water reservoir by hand.
Step 2: Drying the OXYCELL (roof unit)
1.
Close the the OXYZONE unit's screen frame and outlet vents.
2.
Add water by hand until the maximum level is reached and
pour in a bottle of additive 2. Activate the "storage mode"
by pressing the ventilation
and cooling
buttons
simultaneously
for 4 seconds.
LEDs L1 and L3 will flash.
The system will now start to purge (the pumps will switch on at regular intervals).
After about 20 minutes, the system will stop purging and the fan will then dry off
the OXYCELL in the roof unit.
3.
After approx. 1.5 hours all the LEDs will light up and remain lit. This indicates that
the CABIN 400 has been successfully set to storage mode.