![Oxgard Praktika T-04 Installation Manuallines Download Page 32](http://html1.mh-extra.com/html/oxgard/praktika-t-04/praktika-t-04_installation-manuallines_1665030032.webp)
Praktika T-04(K) speedgate
32
•
Turn off the power
•
Wait until LED D11 turns off
•
Press and hold BUT1 button on the card collector board
•
Turn on the power;
•
Press and hold BUT1 button until the card collector provides 1
audio signal, indicating that it is switched to pulse mode of
operation;
Set mode is saved when power is turned off.
6.4.3. "Card Inside" contact set (signal for card collection
confirmation).
NC, NO, and COMM contacts. Relay output operating on a "dry
contact" principle which closes / opens for 1 second transmitting a
confirmation signal of card collection to the ACS controller. NC and
COMM - normally closed connection, NO and COMM - normally open
connection.
6.5. Installation of proximity card reader
MatrixIII proximity card reader is used as an example of installation.
Installation of other models of readers may differ.
6.5.1.
Undo the M4 screw at the rear of the card collector (Fig.
15)