Installation guidelines
31
generates a signal to the OD via "Let Go" contact set (see. article 6.3.1)
and to ACS via "Card Inside" contact set. In such case a green arrow
indicator on the LED panel turns on.
6.4.2. "Free Pass-GND" contact set (signal for passage authorization).
Free Pass and GND contacts. Input that receives a signal from the
ACS controller and allows the passage without card collection (permanent
pass).
In the case of receiving the signal allowing the passage without card
collection, the card reader generates a signal to the OD via "Let Go"
contact set (see. Article 6.3.1). In this case a green arrow indicator on the
LED panel turns on.
Free Pass input of the card collector shall operate in pulse mode
(activation upon contact closure). In pulse mode the voltage is applied to
Free Pass input for a short moment and it authorizes the passage. Another
passage becomes non-authorized when the passage is performed or after 5
seconds.
Pulse mode is set by default, in such case the card collector provides 1
audio signal upon turn-on.
If the card collector provides 2 audio signals, it means that it is set in
potential mode.
Potential mode of the speedgate is not provided, the card collector
shall be set to pulse mode.
In order to switch into pulse mode: