VZR.247800.001
IM
Turnstile CUBE C-03
Installation Manual
23
The AP "dry contact" relay output for the ACS is also installed on the
control board. Its contacts (NC, NO and COM) close or open when somebody is
passing either side through the turnstile. When the turnstile enters the "AP" mode
(pass counting mode), the D9 diode lights up at each pass.
The NC, NO and COM contacts are permanently closed or open in the hold
mode and the D9 diode is constantly on.
– To check the operation of the control board, some LEDs are
installed on it.
1)
D11 is indicative of a pass to the right and relay activation (PassOk1 - to the right).
2)
D10 is indicative of a pass to the left and relay activation (PassOk2 - to the left).
3)
D9 is either constantly on and indicative of the "AP" command activation (in its
hold mode) or it is a signal of each pass (in the pass counting mode). It can be
selected by mode 7 (according to Table 1).