VZR.247800.001
IM
Turnstile CUBE C-03
Installation Manual
22
ATTENTION:
IF THE AP INPUT IS CLOSED, THE COMMANDS FROM
THE PANEL ARE NOT ACCEPTED, SINCE THE ACS HAS A HIGHER
PRIORITY (EXCEPT FOR THE STOP COMMAND).
LEFT and RIGHT inputs can operate in both potential and pulse mode
(they trigger when closed to GND contact). Pulse mode is set by default.
To switch to the potential mode of operation, it is necessary to use the
instructions provided in Table 1. In this case, left/right passing mode is enabled
only for the time when control signal is fed to LEFT/RIGHT inputs.
Free passing mode can be set by sending control signals to both inputs
simultaneously (only in potential control mode). Priority of LEFT and RIGHT inputs
remains unchanged when switching to pulse mode.
Two "dry contact" relay outputs for the ACS are installed on the control
board - Pass Ok1 (to the left) and Pass PassOk2 (to the right).
NO and COMM
– normally open connection, NC and COMM – normally
closed connection.
Triggering of one of the contact groups indicates that a pass has been
made in appropriate direction (PassOk1 - to the right, PassOk2 - to the left). The
"dry contact" closes/opens when the arm is rotated at an angle of 60 degrees and
returns to its original position after complete passage.