15
Current priority;
Automatic fault recovery: The output of the device is disconnected due to a
recoverable fault. Whether to resume output after the fault is removed and the
specified time passes. The unit option "second" and "minute";
Auto-output(hold): The device is powered off during operation, if the auto-output was
enabled, the device automatically restores to the last output state (ON/OFF) after the
setting time;
Note: 1. The rise time is the time required for output from 0 to the rated value, and the fall time is
the opposite. As global parameters, rise and fall time are also applicable to the process of
reference value establishment and output closing in APP mode.
2. Automatic fault recovery is enabled. If the recovery fails for 10 times within 10 minutes or
10 times of the set time, the device will not attempt to recover.
3. Auto-output (hold) function is generally used in unattended scenarios. When the power
grid is off, the device will remember the output state before the power grid is off, and
actively control the output after the program sets the time after the power grid recovers.
Timing Output:
1
.
Time Reference
:
Clock
▼
The First Group
:
Disable
▼
Power On Time
:
08 h 00 m 00 s
Power Off Time
:
10 h 00 m 00 s
The Second Group
:
Disable
▼
Power On Time
:
14 h 00 m 00 s
Power Off Time
:
16 h 12 m 00 s
Table 18: Output timing setting
Time Reference: Selects the clock or power-on time (switch off) as the time reference;
Two groups time setting: Sets two groups of time parameters and sets whether the
two groups of parameters are enabled respectively;
Note: 1. Timing output function can not be used at the same time with the
"
ON/OFF
"
key. If you
need to operate the
"
ON/OFF
"
key manually, you need to turn off the output timing
function.
2. Timing output function does not take effect immediately. It takes effect after the next
power on.