1
1
Back Panel
Figure 1: Back panel
1. DC output terminal: RED "+", BLACK "-"
2. Remote voltage compensation
3. Duct outlet (No obstructions within 10 cm)
4. RS485 interface(Female)
5. CAN interface
6. Dry contact/Analog interface
7. AC Input
1.1 Interface
Figure 2: Interface
Interface
PIN
Function
Interface
PIN
Function
Digital
IO
1
Normally open contact
(Output of the dry contact)
Analog
1
Matching analog1 “+”
2
Common contact
(Output of the dry contact)
2
Matching analog1 “-”
3
Normally closed contact
(Output of the dry contact)
3
Matching analog1 “+”
4
NC
4
Matching analog1 “-”
5
Input of the dry contact
5
Input of the dry contact
6
6
RS485
1
485-A
CAN
2
CAN-L
2
485-B
7
CAN-H
3~9
NC
1/3~6/8 NC
Table 1: Defines of interface
Digital IO interface: PIN 1 to 3 is a dry contact output interface with complementary
functions of normally open and normally close. PIN2 is the common port of the dry
contact. Dry contact output capacity: 1A/30VDC or 0.15A/220VAC; PIN 5 to 6 are dry
contact input interfaces, which can be set for external control of the output, external
fault feedback, or external control of the buzzer;