OWON HDS-N Series Handheld DSO & DMM
8-Advanced Function of Oscilloscope
To make a voltage measurement on CH1, doing the following:
1.
Press the
MENU
key and the function menus are displayed at the right of the screen.
2.
Press the
MENU
▲
or
MENU
▼
key to select
CURS MEAS
. Five options are shown at the
bottom of the screen.
3.
Press
F1
key to select the measurement type
Voltage
. Two purple crossing dashed lines V1
and V2 are shown on the screen.
4.
Press the
F2
key to select the measured channel
CH1
.
5.
Press
OPTION
and display as
—
Cursor 1
—
Cursor 2
When setting
OPTION
▲
or
OPTION
▼
,
V2 will move up and down and the relating
voltage value to the zero position of Channel 1 will show at the bottom of the screen.
Setting
OPTION
◄
or
OPTION
►
,
V1 will move up and down and the relating voltage
value to the zero position of Channel 1 will show at the bottom of the screen, at the same
time the increment shows the absolute value of V1-V2 shown as Fig 52:
Figure 52: Use the Cursor for a Voltage Measurement
When log out submenu, every value will show on the right bottom of the screen as figure 53:
58