14
© 2 Save Energy Limited 2013
on and off correctly. A simple test for this is to press and hold the Comfort (+) button
for 5 seconds. This will activate the Boost mode and turn the boiler on. Check that
the web dashboard Heating widget is now showing that the Boost is activated and the
boiler is running (Red-glow around house icon at top of Heating widget).
8. Handover - Please ensure you handover this document to the householder and direct
them to the Heating & Hot Water Control User Manual available for download by click-
ing on Support & Manuals on the web dashboard (lower right).
Terminal
Description
N
Neutral - Not used, may be used to ‘park’ unused neutral wire.
L
Live - Not used, may be used to ‘park’ unused live wire.
1
Common terminal of Room Sensor latching relay
2
Not used
3
‘Heat Satisfied’ - Normally closed terminal of Room Sensor latching relay
4
‘Call for Heat’ - Normally open terminal of Room Sensor latching relay
Earth continuity connection
OWL Intuition-c Heating Control Room Sensor Backplate Wiring