Installing the Room Sensor
The Room Sensor should be located on an internal wall approximately 1500mm above floor
level, you must use the backplate provided. It should be positioned away from draughts,
direct heat and sunlight. The backplate is suitable for direct wall mounting using two wood
screws No. 6 x 1” or M3.5 x 25mm into correctly sized wall plugs if required. Alterna-
tively mount on to a single gang flush wiring box complying with BS4662, using two M3.5
screws.
1. Check Signal Strength - With the Room Sensor at the chosen installation location
you should now check the signal strength icon shown on the web dashboard Heat-
ing widget. The signal should be at least 2 bars and preferably more. Try moving the
Network OWL closer to the Room Sensor if you have a signal strength problem.
2. Ensure there will be enough space to allow easy screwdriver access to the two cap-
tive screws located at the base of the backplate.
3. Electrical Connections: -
If in any doubt whatsoever, do not continue, but
consult a qualified electrician or heating engineer.
WARNING: ISOLATE THE MAINS SUPPLY BEFORE COMMENCING INSTALLATION
For existing installations
, remove the old room thermostat to expose the wiring back
to the boiler. Check the wiring at both ends to correctly identify which wire is
Live and which is Switched Live.