Network settings
Figure 18: Network settings menu
-
Network type:
Define network IP address type from the Static Mode for fixed IP or Dynamic
Mode for dynamic IP address.
If Static mode is selected, user must fill out IP Address, Subnet Mask, Gateway, DNS Server
and all ports.
If Dynamic mode is selected, IP address will be allocated automatically by DHCP equipment.
If “Apply” button is pressed to update changes,
the system will reboot and user will need to
connect to the camera again using new IP address.
-
IP address:
Define IP address
-
Subnet mask:
Define Subnet Mask
-
Default Gateway:
Define Gateway IP Address
-
Preferred DNS Server:
Define DNS Server IP Address
-
Alternate DNS Server:
Define Secondary DNS Server IP Address
-
HTTP Port:
HTTP port can be set to 80 (default) or in between 1025 to 60000
-
HTTPS Port:
HTTPS port can be set to 443 (default) or in between 1025 to 60000
-
RTSP Port:
RTSP port can be set to 554 (default) or in between 1025 to 60000
Press “Apply” to make effective any modifications.