When using a cable length longer than 3m the supplied filter should be fitted between the
power supply and the camera cable, as shown below.
The installer supplied ethernet cable (Cat5E or better) and RJ-45 endpiece should be fitted to
the connector as shown in Figure 7 before installation of the PTZ into position.
NOTE: The use of a UPS to supply the Camera:
To Comply with EN50130-4 Alarm Standard
–
CCTV for Security Applications it is necessary to
provide an ancillary uninterruptable power (UPS) supply. The UPS must have a Transfer Time
between 2
–
6 ms and a Backup Runtime of greater than 5 seconds for the power level
specified in this manual.
10.
Commissioning and Set-Up
Warning:
Safe working practices must be followed when working with
electricity or at heights.
1.
Ensure all protective covers are in place to prevent accidental contact with live parts
especially where the mains electricity enters the control panel.
2.
Any connections should be carried out by suitably qualified and trained electrical
technicians.
3.
Keep personnel and tools away from the PTZ unit as it may move unexpectedly during set-
up.
4.
Avoid contact with the LED Illuminator unit as it may become hot to touch after prolonged
use.
5.
Ensure all wiring is complete and secured.
6.
Switch power on and observe the PTZ unit go through its calibration routine. This may take 2
–
3 minutes.