2. Exterior of the unit
Maximum safety
- Delta-peak Sensitivity
: when the battery voltage of NiMH/NiCd batteries reaches the
highest point and begins to drop, the charging process with automatically stop.
- Capacity Limit
: the charging process will terminate automatically when the maximum
capacity value that is set is reached.
- Temperature Limit
: the temperature of the battery will rise during the charging process
due to internal chemical reactions. In order to prevent overheating the charging process
will forcibly end if the temperature limit that is set is reached. This function is only available
by connecting an optional temperature probe, which is not included in the package. Avail
-
able from Overlander (SKU: 2598).
- Charge Time Limit
: charging will stop when charge time limit set is reached to avoid any
possible over-charging/over-discharging.
- Input Current Check
: to prevent the battery from being damaged by the input current,
the charger monitors the voltage and ends the process automatically when the voltage
drops below the lowest limit.
- Automatic cooling fan
: the automatic electric cooling fan controls the internal tempera
-
ture of the charger to prevent over-heating.
-
2
-
AC Input (100-240V)
LCD Display
Stop/Main Menu
Balance Lead Port
Charging Lead Port
Temp. Sensor Port
Start/Enter
Cooling Fan
Increase INC(+)
Decrease DEC(-)
Summary of Contents for VSRmini
Page 23: ...Notes 20 ...