28
Transport and storage
Unibox E BV
102272480-V01.04.2020
5. Transport and storage
Transport the product in its original packaging.
Store the product under the following condi-
tions:
Temperature
range
-20°C to +60°C
Relative air
humidity
Max. 95%
Particles
Store dry and free from
dust
Mechanical
influences
Protected from mechani-
cal agitation
Radiation
Protected from UV rays
and direct sunlight
Chemical
influences
Do not store together
with solvents, chemicals,
acids, fuels or similar
substances
6. Installation
6.1 General installation advice
Note the following prior to installation:
• The lower edge of the “Unibox E BV” must
be at least 20 cm above the finished floor.
• The front face of the “Unibox E BV” must
be level with the finished wall.
Should the wall not have been
finished, take the plaster and tile
thickness into account.
• The opening of the wall box unit must face
downwards.
•
The thermostat must not be influenced by
other heat sources.
•
Use the enclosed brackets to align and fix
the “Unibox E BV”.
• For the isolation of the surface heating, we
recommend the additional installation of a
“Unibox RLA” (see Illust. 8 on page 29).
NOTICE
Risk of damage due to lubri-
cants
Seals may be destroyed by greasing
agents or oil.
f
Do not use any greasing agents or
oil for the installation.
f
Flush any dirt particles or grease or
oil residues out of the pipework.
f
Consider the latest technical status
(e.g. VDI 2035), when choosing the
operating fluid.
1
2
3
4
5
6
7
8
Illust. 7: Installation cross section
(1)
Block or stud wall
(2)
Unibox E BV
(3)
Plaster
(4)
Pipe conduit unit (separate accessory)
(5)
Edge insulating strip (separate acces-
sory)
(6)
Screed
(7)
Protective tube (separate accessory)
(8)
Branch pipe
Summary of Contents for Unibox E BV