12

a)  Connect the actuator to the controller relay R13.
b)   If no installation scheme with zone loading has been 

activated before, zone loading has to be activated 
separately with due consideration of the controller 
description!

c)   Please make sure that the connected cables are 

strain-relieved. 

d)  Close the controller casing.
e)  Switch on current supply.

The extension set is now ready for operation. 

7  Maintenance

To guarantee a perfect operation of the extension set, 
it  is  recommended  to  have  it  maintained  by  a 
specialist heating company at least once a year. 

The following work should be done:
–  Leakage test:
 

– of all valves and components.  

–  Functional control:
 

– Check diverting and mixing valve.

 

– Check actuators.

8   General  conditions  of  sales 

and delivery

Oventrops general conditions of sales and delivery 
valid at the time of supply are applicable.

           NOTE
Control of an external circulation pump can be 

carried out via the controller, with follow-up time 

if required.

Summary of Contents for Regucor Series

Page 1: ...hpersonal dazu das Erweiterungs Set fachgerecht zu installieren und in Betrieb zu nehmen Mitgeltende Unterlagen Anleitungen aller Anlagen komponenten sowie geltende technische Regeln sind einzuhalten...

Page 2: ...chen Anlagen auszuf hren und m gliche Gefahren selbstst ndig zu erkennen Elektrofachkraft ist aufgrund ihrer fachlichen Ausbildung Kenntnisse und Erfahrungen sowie Kenntnis der einschl gigen Normen un...

Page 3: ...25 6 5 21 5 Aufbau und Funktion 5 1 bersicht Abb 5 1 Beladung Hochtemperaturbereich Abb 5 2 Beladung Niedertemperaturbereich Zeta Werte bezogen auf den Rohrinnendurchmesser nach DIN EN 10255 kVS Wert...

Page 4: ...T Bei der Montage d rfen keine Fette oder le verwendet werden da diese die Dichtungen zerst ren k nnen Schmutzpartikel sowie Fett und lreste sind ggf aus den Zuleitungen he rauszusp len Bei der Auswah...

Page 5: ...eischalten Gegen Wiedereinschalten sichern Spannungsfreiheit feststellen Erden und kurzschlie en Ggf Benachbarte unter Spannung stehende Teile abdecken Bei Besch digung der Isolation die Spannungs ver...

Page 6: ...it 7 Wartung und Pflege Um einen einwandfreien Betrieb des Erweiterungs Sets zu gew hrleisten wird mindestens 1 mal pro Jahr eine Wartung durch einen Heizungsfachbetrieb empfoh len Folgende Arbeiten s...

Page 7: ...uctions serve the installer to install the extension set professionally and to put it into operation Other valid documents manuals of all system components as well as valid technical rules must be obs...

Page 8: ...ge of the relevant standards and regulations the gas and water specialist is in a position to carry out any work at gas installations and to recognize possible dangers Electrician Due to professional...

Page 9: ...Construction and function 5 1 Summary Illustr 5 1 Loading high temperature section Illustr 5 2 Loading low temperature section Zeta values related to the inner pipe diameter according to DIN EN 10255...

Page 10: ...cylinder CAUTION Do not use any greasing agents or oils for the installation as these can destroy the seals Any dirt particles or grease or oil residues must be flushed out before the extension set i...

Page 11: ...rved during installation and cabling Disconnect Protect against accidental restart Check that no voltage is present Earth and short circuit If necessary Cover adjacent live parts In case of damage to...

Page 12: ...dy for operation 7 Maintenance To guarantee a perfect operation of the extension set it is recommended to have it maintained by a specialist heating company at least once a year The following work sho...

Page 13: ...f rence Les notices de tous les composants du syst me ainsi que les r gles techniques d usage en vigueur sont respecter 1 2 Conservation des documents Cette notice d installation et d utilisation doi...

Page 14: ...tuer tous les travaux sur les installations de chauffage y compris sur celles fonctionnant au gaz et d en reconna tre tous les dangers possibles L lectricien Il en va de m me pour l lectricien qui est...

Page 15: ...nt 5 1 Vue d ensemble Fig 5 1 Stratification en partie haute temp rature du ballon Fig 5 2 Stratification en partie basse temp rature du ballon Les valeurs Zeta se rapportent au diam tre int rieur du...

Page 16: ...de la vidange du ballon d eau chaude CAUTION Ne pas utiliser de graisse ou d huile lors du montage celles ci peuvent endommager les joints Si n cessaire des impuret s ou r sidus de graisse ou d huile...

Page 17: ...e en service intempestive Constater l absence de tension Raccorder la terre et court circuiter Si n cessaire Couvrir des composants adjacents sous tension En cas d endommagement de l isolation couper...

Page 18: ...mand de faire entretenir le jeu d extension par une entreprise qualifi e au moins une fois par an afin de garantir un bon fonctionnement du jeu d extension Les travaux suivants doivent tre effectu s l...

Reviews: