4.3
Examples of External Control
Remote Record Switch
Connect record switch to pins 6 & 3, Wake-
up & Record.
NB:
When the switch opens, the unit will
enter “Stop” or “Record-pause” depending on
the “Record Pause” setting in the “Set
System Options” menu. See Section 3.7,
Page 18.
6 Wake-up
3 Record In
7 Ground
Record
Switch
External Alarm Sensor:
Connect sensor to pin 1, the Alarm-start
input.
In the in the “Set alarm options”
advanced menu set “on open” or “on
closed” and the alarm record rate (in
frames per second) the alarm duration
(see Section 3.4, page 14).
1 Alarm-start
7 Ground
PIR Detector
Alarm Start / Stop:
Connect switch / sensors to the Alarm-
start and Alarm-stop inputs.
In the in the “Set alarm options”
advanced menu set to “start / stop”, the
alarm record rate in frames per second
(see Section 3.4, page 14).
1 Alarm-start
7 Ground
2 Alarm-stop
Alarm
Start
Switch
Alarm
Stop
Switch
Remote Start / Stop Switch:
Connect start switch to pins 6 & 5, Wake-
up and Chain-in.
Connect stop switch to pin2, Alarm-stop.
In the in the “Set alarm options”
advanced menu ensure alarms are set to
“disabled”.
NB:
Each recording will make a new file.
6 Wake-up
5 Chain-in
2 Alarm-stop
7 Ground
Start
Switch
Stop
Switch
5 Ethernet Port