background image

E-822-9-E

1. GENERAL ..............................................................................................................................3

FEATURES

 ........................................................................................................................3

2. PART NAMES.........................................................................................................................3
3. OUTLINE DIMENSIONS ........................................................................................................3
4. INSTALLATION ......................................................................................................................4

4.1 Installation Location .........................................................................................................4
4.2 Mounting Panel ................................................................................................................4
4.3 Installation Procedure ......................................................................................................4

5. WIRING ..................................................................................................................................5

5.1 Cables for Field Wiring ....................................................................................................5
5.2 Wiring Connections..........................................................................................................5
5.3 Terminal Block for External Connections .........................................................................5

6. OVERALL BLOCK DIAGRAM ................................................................................................6
7. CONVERSION FORMULA .....................................................................................................6
8. CHANGING THE PULSE GENERATOR TYPE, METER SIZE (nominal bore), 

 

 METER ERROR, AND SCALER SETTINGS .........................................................................7

9. PULSE/ANALOG CONVERTER BOARD (OPTION) .............................................................8
10. OPERATION .........................................................................................................................8

10.1 Preparation Before Operation ........................................................................................8
10.2 Operation .......................................................................................................................8

11. TROUBLESHOOTING ..........................................................................................................8
12. OPERATION FLOW CHART ................................................................................................9
13. PRODUCT CODE EXPLANATION .................................................................................... 11
14. TOTAL COUNTER AND OUTPUT UNITS .......................................................................... 11
15. GENERAL SPECIFICATIONS ............................................................................................12

CONTENTS

This manual uses the precaution words 

"

NOTE

", "

CAUTION

", and "

WARNING

" as explained below:

NOTE:

Notes are separated from the general text to bring the user's 

attention to important information.

CAUTION:

Caution statements inform the user of hazards or unsafe practices 

which could result in minor personal injury or product/property 

damage.

WARNING:

Warning statements inform the user of hazards or unsafe practices 

which could result in severe personal injury or death.

Summary of Contents for EL4061

Page 1: ...e throughout its life this manual offers the operator the necessary installation operation and maintenance information Be well familiar with these instructions before you place the computer in service...

Page 2: ...TION 8 10 1 Preparation Before Operation 8 10 2 Operation 8 11 TROUBLESHOOTING 8 12 OPERATION FLOW CHART 9 13 PRODUCT CODE EXPLANATION 11 14 TOTAL COUNTER AND OUTPUT UNITS 11 15 GENERAL SPECIFICATIONS...

Page 3: ...S 3 OUTLINE DIMENSIONS OPERATION INDICATOR LED RED 7 DIGIT TOTAL COUNTER UNITS OF MEASURE NAMEPLATE PRESSURE SETTING SWITCH UNITS OF MEASURE MPa SEFT TEST BUTTON TAG NO NAMEPLATE ENCLOSURE MTG FITTING...

Page 4: ...a minimum thickness of 1 6 millimeters Suggested thickness is approximately 3 2 mm 2 If it is desired to mount instruments side by side dimensions in Fig 4 1 are suggested 3 Recommended mounting heig...

Page 5: ...ve interference 3 Using crimp style terminals for wiring connections ensure good electrical connections Terminals are found on the back of the computer 4 Good practice is to provide an allowance of 30...

Page 6: ...TTING RANGE 0 00 to 1 99MPa PRESSURE SETTING SWITCH 7 DIGIT TOTAL COUNTER LED TEST CHECK RUN SELECT SWITCH FRONT PANEL SIZE NOM DIA SETTING SWITCH ONE SHOT MULT CIRCUIT SINGLE CHIP MICROPROCESSOR 6 OV...

Page 7: ...7567 4 C 150 2 422 5 40 0 04363 D 200 7 021 6 40 0 04556 E 250 13 54 7 50 0 09655 F 300 23 24 NOTE Separate rotary switch positions are allocated because positions 2 and 3 5 and 6 7 and 8 have differe...

Page 8: ...CK mode CHECK mode operation is described on Sec 12 10 2 Operation 1 Turning on power The LED will light up about a second later and stays on for about two seconds before the RUN mode is indicated 2 A...

Page 9: ...HECK MODE FLOW CHART CHECK MODE LED blinks for 2 sec Total counter counts 3 pulses LED lights in synchronism LED blinks for 2 sec LED lights for pre set number at in tervals of 0 5 sec LED lights for...

Page 10: ...rotary switch position currently set up Postitions A B C D E and F are indicated by blinking 10 11 12 13 14 and 15 times respectively NO NO YES YES Meter error set or not Shows whether positive correc...

Page 11: ...rotary switch establishes value which agrees with meter size For rotary switch positions see Section 8 2 Setting of Meter Size nominal bore Meter Error Internal jumper establishes corrections in a ran...

Page 12: ...ove Always N N Always N Output item 2 Pulse output N N None Always N N Always N Output item 3 Analog output N N None A 2 1 to 5V A 5 4 to 20mA A P 0 to 10mV A Q 10 to 50mV A R 0 to 100 A Z Z Special A...

Page 13: ...erter output provided 0 to 10mV 4 F I converter output provided 4 to 20mA 5 F I converter output provided 10 to 50mA 7 F I converter output provided 0 to 100 A 9 Other than above 1 Always 1 Instrument...

Page 14: ...E 822 9 E All specifications are subject to change without notice for improvement 2019 04 Revised E 822 9 E 1...

Reviews: