13.TOTAL COUNTER AND OUTPUT UNITS

NOTES:

1

Because the max. frequency the magnetic counter can respond is 5Hz, it is necessary 

          that a requirement

 

 

 

Max. flowrate

kg/h

     

            

3600

×

Totalizer unit

kg

5

Hz

be satisfied. 

          Hence,

 

a 1/10 scale may, under certain conditions, not be available depending on 

          given operating conditions.

2

Provided with remote instantaneous flowrate output.

Delta Flowmeter

Nominal Diameter

Totalizer

Least Significant Digit, kg

Open Collector Mass Pulse Output

kg

Analog Output

Min, Full Scale

Flowrate,kg/h 

2

mm

Scaling

1/10 

1

1/100

1/1

1/10

1/100

15

0.01

0.1

0.001

0.01

0.1

15

25

0.01

0.1

0.001

0.01

0.1

15

40

0.1

1

0.01

0.1

1

150

50

0.1

1

0.01

0.1

1

150

80

1

10

0.1

1

10

1500

100

1

10

0.1

1

10

1500

150

1

10

0.1

1

10

1500

200

10

100

1

10

100

15000

250

10

100

1

10

100

15000

300

10

100

1

10

100

15000

ITEM

DESCRIPTION

Input

Pulse Generator Delta meter preamplifier PA15 or 25
Signal Levels

"1": 20mA min.; "0": 4mA max.

Overcurrent Detection PA15 and 25: An erratic probe is indicated above 27

±

4mA (LED flickers).

Pressure

Front-panel digital switch establishes the operating pressure

(0.00 to 1.99MPa in 0.01MPa steps).

Meter Size (nominal 

bore)

Internal rotary switch establishes value which agrees with meter size.

For rotary switch positions, see Section 8.(2) "Setting of Meter Size (nominal bore)."

Meter Error

Internal jumper establishes corrections (in a range of from 0.0 to 

±

7.5% in 0.5% steps).

Scaling (totalizer)

Internal jumper establishes the factor of frequency reduction (1/10 or 1/100).

Scaling (Output)

Internal jumper establishes the factor of frequency division (1/1 or 1/10 or 1/100).

Pulse Output after Conversion 

in Terms of Mass

Open collector max. rating: 30V DC, 0.1A

Pulse width: 1-4ms., 40-60ms. (with 1/10 or 1/100 reduction)

Analog Output after 

Conversion in Terms of Mass An analog output of instantaneous flowrate in terms of mass (option)
Accumulated Total Display 7-digit electromagnetic counter
Seft-Test Function

±

0.3% of reading

Computing Accuracy

Depressing the self-test button advances the reading by 3 counts when functioning correctly.

Power Supply

100, 110/115, 200, 220/230V AC, 50/60Hz

Power Consumption

7VA max.

Ambient Temperature

10

 to 

50

Insulation Resistance Across power terminals bundled and ground terminal: Greater than 10M

Ω

 with 500V DC Megger

Withstand Voltage

Across power terminals bundled and ground terminal: 1500V AC for one minute

Installation

Panel mount

Finish

Instrument frame (resin molding): Munsell N1.5 
Enclosure (steel sheet): Munsell N6.0

Mass

1 kilogram approx.

14.GENERAL SPECIFICATIONS

Summary of Contents for EL4061

Page 1: ...e throughout its life this manual offers the operator the necessary installation operation and maintenance information Be well familiar with these instructions before you place the computer in service...

Page 2: ...TION 8 10 1 Preparation Before Operation 8 10 2 Operation 8 11 TROUBLESHOOTING 8 12 OPERATION FLOW CHART 9 13 PRODUCT CODE EXPLANATION 11 14 TOTAL COUNTER AND OUTPUT UNITS 11 15 GENERAL SPECIFICATIONS...

Page 3: ...S 3 OUTLINE DIMENSIONS OPERATION INDICATOR LED RED 7 DIGIT TOTAL COUNTER UNITS OF MEASURE NAMEPLATE PRESSURE SETTING SWITCH UNITS OF MEASURE MPa SEFT TEST BUTTON TAG NO NAMEPLATE ENCLOSURE MTG FITTING...

Page 4: ...a minimum thickness of 1 6 millimeters Suggested thickness is approximately 3 2 mm 2 If it is desired to mount instruments side by side dimensions in Fig 4 1 are suggested 3 Recommended mounting heig...

Page 5: ...ve interference 3 Using crimp style terminals for wiring connections ensure good electrical connections Terminals are found on the back of the computer 4 Good practice is to provide an allowance of 30...

Page 6: ...TTING RANGE 0 00 to 1 99MPa PRESSURE SETTING SWITCH 7 DIGIT TOTAL COUNTER LED TEST CHECK RUN SELECT SWITCH FRONT PANEL SIZE NOM DIA SETTING SWITCH ONE SHOT MULT CIRCUIT SINGLE CHIP MICROPROCESSOR 6 OV...

Page 7: ...7567 4 C 150 2 422 5 40 0 04363 D 200 7 021 6 40 0 04556 E 250 13 54 7 50 0 09655 F 300 23 24 NOTE Separate rotary switch positions are allocated because positions 2 and 3 5 and 6 7 and 8 have differe...

Page 8: ...CK mode CHECK mode operation is described on Sec 12 10 2 Operation 1 Turning on power The LED will light up about a second later and stays on for about two seconds before the RUN mode is indicated 2 A...

Page 9: ...HECK MODE FLOW CHART CHECK MODE LED blinks for 2 sec Total counter counts 3 pulses LED lights in synchronism LED blinks for 2 sec LED lights for pre set number at in tervals of 0 5 sec LED lights for...

Page 10: ...rotary switch position currently set up Postitions A B C D E and F are indicated by blinking 10 11 12 13 14 and 15 times respectively NO NO YES YES Meter error set or not Shows whether positive correc...

Page 11: ...rotary switch establishes value which agrees with meter size For rotary switch positions see Section 8 2 Setting of Meter Size nominal bore Meter Error Internal jumper establishes corrections in a ran...

Page 12: ...ove Always N N Always N Output item 2 Pulse output N N None Always N N Always N Output item 3 Analog output N N None A 2 1 to 5V A 5 4 to 20mA A P 0 to 10mV A Q 10 to 50mV A R 0 to 100 A Z Z Special A...

Page 13: ...erter output provided 0 to 10mV 4 F I converter output provided 4 to 20mA 5 F I converter output provided 10 to 50mA 7 F I converter output provided 0 to 100 A 9 Other than above 1 Always 1 Instrument...

Page 14: ...E 822 9 E All specifications are subject to change without notice for improvement 2019 04 Revised E 822 9 E 1...

Reviews: