E-880CM-1-E
0
STX
STX
R L
ETX
BCC
CR LF
BCC
CR LF
Error item 1
Error item 2
Error item 1
Error item 2
* *
STX
STX
R L
F 0
F 0
ETX
CR LF
0 1
0 1
0 0
0 0 1 6
02 30 31 46 30 52 4C 30 30 03
0D 0A
* *
ETX
CR LF
03
0D 0A
02 30 31 46 30 30 30
30 33
31 36
32 34 31 35 33 30 30 32 30 30 33 32 34 31 35 33 30 30
0 3 2 4 1 5 3 0 0 2 0 0 3 2 4 1 5 3 0 0
Error item 3
Error item 20
33 34 30 33 32 34 31
30 30
35 33
30 30 30 30 30 30 30 30 30 30 30
Code
Code
Code
Code
No.
Date
Time
Time
No.
Date
Error item 3
Error item 20
Time
No.
No.
Time
Date
Date
ETX
• • •
• • •
3 4 0 3 2 4 1 5 3 0 0
0 0 0 0 0 0 0 0 0 0 0
Client
No.
Host
No.
Func.
code
Client
No.
Host
No.
Res-
ponse
Host system
PC, etc.
Client system
EL4511
Host system
PC, etc.
Client system
EL4511
6.14 Error Logging Read Command (RL)
6.14.1 Description
With this command, you can read the logging record of error events in batch or individually.
Function No. 00: Batch read
01
…
: Read error events individually.
Error No. is the same as the byte number of error status read command. (00: "None")
※
A total of 20 events can be stored in error record logging, error start/end discriminated. If error start/
end count exceeds 20 in the course of logging, overwriting takes place at the
fi
rst data. Accordingly,
data stored in the first area of logging data is not necessarily the oldest one. It follows that you
specify the data area No., rather than the sequential order of data, when you specify the contents
to be read with this command.
※
"Year" is not included in the date to be read in error logging.
Start/end code 0 : Start 1 : End
6.14.2 Command/Response
①
Batch read
Example : Batch read