L-770HP--E
E-454-1-E
8
●
How to treat the dedicated cable terminal
●
Wire connection method
(1) Open the sensor unit terminal box.
(2) Connect the cables by matching the color of cable
and the terminal block.
(For the black terminal, connect the shielded wire)
Sensor unit side
Sensor unit side
Transmitter side
Transmitter side
100mm
9mm
Red
Brown
Elastic tube (large)
Cut the shielded wire except for
the red / brown shielded wire.
50mm
9mm
Sensor unit terminal box
Brown
Red
Black
Orange
Yellow
Green
Blue
Purple
Gray
White
Shielded wire: black
Cable clamp
Wiring name plate
Separated cover
I S CONNECTION
SHIELD
L−
D−
G
R−
R+
D+
L+
TA
Tb TB
Brown
Red
Black
Orange
Yellow
Green
Blue
Purple
Gray
White
Brown
Red
Black
Orange
Yellow
Green
Blue
Purple
Gray
White
(1) Remove approximately 100mm of sheath of cable.
(2) Protect red / brown shielded wire with black tube.
(3) Cut all shielded wires except for the red / brown
shielded wire.
(4) Protect the shielded wires with the elastic tube (large).
(5) Cut approximately 9mm of cable insulation.
(Rod crimp terminal is not necessary)
(1) Remove approximately 50mm of sheath.
(2) Combine red / brown, green / white, blue / gray,
purple / yellow / orange wires and trim the 9mm tip to
a thickness of one wire. Protect the wire with black
tube.
(3) Cut approximately 9mm of cable insulation.
(Rod crimp terminal is not necessary)
(1) Remove the cable clamp.
(2) Connect the cables by matching the color of cable
and the terminal block according to the wiring name
plate.
(For the black terminal, connect the shielded wire)
(3) Fix the cables with the cable clamp as shown in the
figure.
(The cable clamp has the same electric potential as
the "G" black terminal)