6
Rigging and Safety
The recommended rigging position of the Creamsource is with the cooling fins in a vertical
orientation, as this allows for the best natural cooling of the unit. It can be mounted in other
positions; however care must be taken not to smother the cooling fins on the back of the unit.
It is advisable to keep a 10cm clearance around the unit to maintain airflow.
The yoke arm accepts a 5/8 inch spigot, so is compatible with a large range of stands and other
rigging equipment. With the supplied spigot, the unit is suitable for floor stand mounting only.
If the unit is to be mounted suspended, it is necessary to replace the standard
spigot with a 28mm DIN or Euro spigot (For example Doughty T74705)
If rigging the unit above people, from vehicles, moving platforms, or hanging from any rigging,
be sure to secure the unit through the safety-cable holes located at each end of the Creamsource
using approved and correctly rated safety cables, chains or carabiners. Both safety chain holes
should be used.
For a Creamsource Doppio, use appropriate
safety cable for 10kg load
For a Creamsource Mini, use appropriate safety
cable for 6kg load
Rigging Power Supply
The CS-PSU-450 power supply unit has two 3/8” threaded
inserts on its base for rigging purposes. These can be used to
secure the unit to a stand or other structure.
Do no use bolts which protrude more than 25mm
(1 inch) into the power supply housing
!
!