12 | Ottobock
To block the rotation, turn the cover in clockwise direction after inserting
the stud (fig. 1, item 1).
To loosen the stud, rotate the cover in counterclockwise direction. The stud
will be driven automatically out of the locking mechanism (fig. 1, item 1).
Two more movement levels will be created by connecting the 10V26 Flexion
Device to the 10V9 or 10V10 Wrist Unit without Ratchet or 10V25 Wrist
Unit without Ratchet.
The flexion of the Wrist Unit without Ratchet can be blocked by the lever
(fig. 2, item 1).
3 Technical Data
Article number
10V9
10V10
10V25
Weight (g)
90
110
165
Total weight (mm)
26
47
4 Handling
4.1 Assembly
INFORMATION
Follow all processing and safety instructions by the adhesive manufacturer.
NOTICE
Damage due to improper use of adhesive.
To guarantee a solid bond,
clean the respective areas with acetone before applying the adhesive.
Do not touch the areas after you have degreased them and when the
acetone has dried up, apply the adhesive immediately.
10V9 / 10V10
1) A laminated forearm socket must be fabricated using the appropriate
lamination dummy (dia. 50 mm).
2) Loosen the four attachment screws of the lamination ring.