![otometrics madsen itera ii Reference Manual Download Page 70](http://html.mh-extra.com/html/otometrics/madsen-itera-ii/madsen-itera-ii_reference-manual_1658678070.webp)
Note
•
If you connect an external microphone, which can be the monitor headset or the gooseneck
microphones, to EXTERN MIC, this automatically disables the internal microphone (INTERN MIC.). If
no external microphone is connected, the corresponding internal microphone will automatically be
selected.
CD
If you press
CD
, CD_1 or CD_2 is shown briefly in the display.
The CD_1 input is Channel 1 (left) on the recording.
The CD_2 input is Channel 2 (right) on the recording.
Switching between input signals
You can switch between input channels:
1. Press and hold
MIC.
or
CD
, and simultaneously press
L <--> R
.
The display will show the input channel you have selected, and flashes as long as you keep pressing the button.
2. If you wish to switch between all available inputs, turn the frequency selector while you press
MIC.
or
CD
.
This will give you get access to all possible microphone and CD options. If you select
CD
for one ear and the micro-
phone for the other, both
MIC
and
CD
will light up.
One-channel or two-channel testing
If you wish to operate MADSEN Itera II as a one-channel or a two-channel speech audiometer, select either the same input
to both ears (one-channel) or select two different inputs (two-channel).
When you use two-channel testing, there are 16 possible combinations of inputs.
•
Regular one-channel monoaural testing (default)
CD_1 is the default input channel for right or left ears. Masking is available for the opposite ear.
•
Two-channel monoaural testing
This test requires special routing. See
.
Adjusting input sensitivity
You can adjust the strength of the input signal:
1. Press and hold the selected input button and use the
right LEVEL
selector while you check the bar indicator at the
bottom of the display.
2. Make sure that the speech signal is reproduced correctly with the dB value stated in the display: the VU meters must
move into line with "0 dB" on the VU meter scale.
7.1.2
Selecting masking for speech testing
If you select masking, the masking signal is displayed in the first line of the display. You can select
–
Speech noise (SPN), or
–
White noise (Wide Band Noise - WBN).
1. To adjust the masking signal type selection, select
SETUP
,
70
Otometrics - MADSEN Itera II
7 Speech testing
Summary of Contents for madsen itera ii
Page 1: ...MADSEN Itera II Reference Manual Doc No 7 50 0860 EN 26 Part No 7 50 08600 EN ...
Page 10: ...1 Introduction to MADSEN Itera II 10 Otometrics MADSEN Itera II ...
Page 52: ...4 Navigating in the OTOsuiteAudiometry Module 52 Otometrics MADSEN Itera II ...
Page 60: ...5 Preparing for testing 60 Otometrics MADSEN Itera II ...
Page 68: ...6 Tone testing 68 Otometrics MADSEN Itera II ...
Page 74: ...7 Speech testing 74 Otometrics MADSEN Itera II ...
Page 86: ...9 Managing Data and Results 86 Otometrics MADSEN Itera II ...
Page 110: ...15 Maximum non destructive voltage 110 Otometrics MADSEN Itera II ...
Page 118: ...18 Standards and safety 118 Otometrics MADSEN Itera II ...