Tab. 1.2:
Technical characteristics (Cont’d)
Parameters
Type/Value
Environmental characteristics (Radio Unit module)
Operative temperature
-20° to +55°C
Storage temperature
-40° to +85°C
Relative humidity
10 to 95% at 50°C non condensing
Cold test
ETS 300 019-1-5 class 5.2 (within the
operative temperature range)
Dry hot test
ETS 300 019-1-5 class 5.2 (within the
operative temperature range)
Air temperature change test
ETS 300 019-1-5 class 5.2
Damp heat cyclic test
ETS 300 019-1-5 class 5.2
Protection to dust and water
IP54
Shock and vibrations
ETS 300 019 1-5 IEC class 5M3
Environmental characteristics (Front Panel module)
Operating temperature range
-20 to + 60°C
Storage
-40 to + 85°C
Relative humidity
10 to 95% at 55°C
Protection to dust
IP54
Shock and vibrations
ETS 300 019 1-5 IEC class 5M3
Transmitter characteristics
Modulation
π
/4 DQPSK
Maximum power in antenna
10W (Tetra Power Class 2)
Power of undesired output in non active
transmission state
In compliance with EN 300 392-2
Adjacent channel power due to modulation
In compliance with EN 300 392-2
Adjacent channel power due to commutation
transistors.
In compliance with EN 300 392-2
Undesired emissions far from the carrier
In compliance with EN 300 392-2
Receiver characteristics
Sensitivity
In compliance with EN 300 392-2
Rejection of co-channel
In compliance with EN 300 392-2
Blocking characteristic
In compliance with EN 300 392-2
Rejection of spurious response
In compliance with EN 300 392-2
Rejection of inter-modulation response
In compliance with EN 300 392-2
Conducted emission undesired
In compliance with EN 300 392-2
Irradiated emission undesired
In compliance with EN 300 392-2