WiJET.Video Technical Manual
Page 19 of 29
Communication with another radio (a station or an AP), however, can be successful
only if the other radio also is set up to communicate in the “Open system” mode. When
the “Shared key” option is chosen, the “Encryption” page of the Utility program must be
properly filled out. See “Encryption” page for details.
Transmission key selection:
One of the four default keys needs to be selected for
transmitting data frames. The radio can de-encrypt received data encrypted in any one
of the four default keys, but it uses only one of the default keys for transmitting its data.
Operation Mode:
Automatic or Manual. This is to set the WiJET.Video to be in
automatic (default) or manual operation mode. Automatic mode will make the unit
automatically select an unused SSID AND a clearest channel when boots up. Under
the Manual mode, the user can select SSID and channel for WiJET.Video to operate.
4.3.3 Administration
When you click on the Administration hyperlink, you will see the following page as on
Figure 4.6. Detail of each field is described below.
Figure 4.5: Administration Screen Page
User Name:
you can change the default user name of “Admin” to something else you
desire. The character limit is 16 characters for this field.
Enter New Password:
This allows you to change the password of the unit. The default
is “public”, but you can change it to anything you like. Character limits on the password
is also 16 characters.
Confirm New Password:
To confirm the password that you entered in the above field.