DALIeco LS/PD LI, Instal Operation

1 General 

information

1.1  Symbols and abbreviations used in this manual

Bullet point, listing

1.

Numbered steps in specifi ed order

 

2.2

Reference to section (e.g. 2.2.) or separate manual (without number)

 

13

Figure reference (e.g. to Fig. 13)

SP

Abbreviation for "

S

hort 

P

ress / Press button briefl y" (<0.5 s)

VLP

"

V

ery 

L

ong 

P

ress / Press button for very long duration" (>10 s)

1.2 Intended use

This product is specially developed and intended for use with light management systems for 

lighting systems. Any other use is not in conformity with its intended use.

2  Assembly and installation

2.1  Sensor and networking 

 4 

Names of components 

 

3a

(1) 

Infrared re LED display

(2) 

Sensor button (hidden in housing)

(3) Presence 

sensor

(4) 

2 Shutter (set detection range/presence)

(5) Sensor 

housing

(6) 

Connection for sensor cable (4p4c)

(7) Cover

(8) Brightness 

sensor

(9) Retaining 

tangs

Connection of max. 4 sensors (3) via Y-connector (4) and sensor cable (2) at the sensor connec-

tion 

 

5

.

2.2 Connection 

Connection of the sensor cable with 2 4p4c plugs at the corresponding 4p4c sockets of the 

control unit and the sensor 

 

4

.

2.3  Assembly options for the luminaire

There are 2 different covers for this as well as the possibility of individually fi tting into the lumi-

naire housing:

• 

Cover (2) for installing the sensor externally through the opening (1) in the luminaire housing 

 

3c

. The cover is placed on the sensor prior to installing the sensor and the two together 

are inserted in the opening in the luminaire housing.

• 

Cover (2) for installing the sensor internally 

 

3d

. The cover is placed on the sensor hous-

ing. If the sensor is in the correct mounting position, the raised surface of the cover will sit 

flush in the luminaire opening (1).

• 

Internal sensor installation without separate cover 

 

3b

The openings in the luminaire housing (1) must be made to accurately fit with the sensor (2).

Retaining tangs (9) on the bottom of the sensor for simple assembly on corresponding counter-

part 

 3a

.

2.4 Assembly-location

 

 

6

Summary of Contents for DALIeco LS/PD LI

Page 1: ...DALIeco LS PD LI...

Page 2: ...2 DALIeco LS PD LI F1 F2 F3 F4 Prog 100 h Ch 2 Ch 1 Holiday 50 mm 0 2 17 0 2 57 mm 0 2 20 0 2 17 0 2 48 mm 0 2 15 0 2 1 9 mm 1 8 mm 1 2...

Page 3: ...0 2 6 7 0 2 14 0 0 2 3 2 6 7 0 2 17 3 42 5 9 75 4 5 2 1 10 8 0 1 10 8 0 1 0 5 0 6 2 1 2 1 9 2 3 4 6 7 8 9 5 14 0 0 2 0 5 2 4 R 1 8 mm 0 2 2 1 41 0 0 2 55 4 1 0 15 4 2 0 0 5 2 4 R 0 6 mm max 2 1 3a 3c...

Page 4: ...4 Sensor GND Sync 072 AM Test C max 1 5 1 5 h h Sensor DALI 1 DALI 1 DALI 2 DALI 2 GND Sync 220 240V 50 60Hz 40mA 2 3 4 1 4 6 5...

Page 5: ...5 max 90 min 40 7...

Page 6: ...8 Helligkeitssensor 9 Befestigungsnasen Anschluss von max 4 Sensoren 3 via Y Connector 4 und Sensorkabel 2 am Sensoranschluss Steuereinheit 1 5 2 2 Anschluss Anschluss des Sensorkabels mit 2 Steckern...

Page 7: ...ungen einzuschalten Sensor LED blinkt rot f r 3 Sekunden bzw auszuschalten Sensor LED leuchtet rot f r 3 Sekunden 2 Sensor Taste dr cken VLP um Auto Setup und damit die Kalibrierung zu starten Nach 3...

Page 8: ...max 4 sensors 3 via Y connector 4 and sensor cable 2 at the sensor connec tion 5 2 2 Connection Connection of the sensor cable with 2 4p4c plugs at the corresponding 4p4c sockets of the control unit...

Page 9: ...sor LED flashes red for 3 seconds or off sensor LED illuminated red for 3 seconds 2 Press the sensor button VLP in order to start Auto Setup and thereby calibration After a 3 minute calibration the li...

Page 10: ...nexi n de m x 4 sensores 3 via conector en Y 4 y cable del sensor 2 en la conexi n en la unidad de control 1 5 2 2 Conexi n Conexi n del cable de sensor con 2 conectores 4p4c en las clavijas correspon...

Page 11: ...el LED del sensor se pone en luz fija roja durante 3 segundos 2 Pulse el bot n del sensor VLP para arrancar el Auto Setup configuraci n autom tica y con ello la calibraci n Despu s de 3 minutos de cal...

Page 12: ...8 Capteur de clart 9 Languettes de fixation Brancheement de max 4 capteurs 3 via connecteur Y 4 et c ble de capteur 2 sur le branche ment du capteur de l unit de commande 1 5 2 2 Branchement Branchem...

Page 13: ...eindre la LED du capteur s allume en roug pendant 3 secondes 2 Appuyer sur le bouton du capteur VLP pour d marrer le setup automatique et le calibrage Apr s le calibrage de 3 minutes l clairage cligno...

Page 14: ...t 9 Nottolini di fissaggio Collegamento di max 4 sensori 3 via Y Connector 4 e cavo sensore 2 al collegamento senso re unit di comando 1 5 2 2 Collegamento Collegamento del cavo sensore con 2 spine 4p...

Page 15: ...i e o disattivare LED sensore lampeggia rosso per 3 secon di 2 Premere il tasto sensore VLP per avviare l auto setup e con ci la calibratura Dopo 3 minuti di calibratura la lampada inizia a lampeggiar...

Page 16: ...OSRAM AG Steinerne Furt 62 86167 Augsburg Germany www osram com CB1910809 G10414479...

Reviews: