LEXPERT PROFILE L
7
5. POWER
Yellow/Green
5
Rotate the zoom as the arrow shown, align it with two triangles sign, and tighten the two screws on two sides of the unit to fix the zoom -
Fig. 4
The power requirements are as follows:
Voltage: AC100-240V, 50/60Hz
Power: 345W
The fixture is supplied with a power cable (14 AWG brown and blue cables) installed ready for connection.
Power cord colors -
Fig. 5
Lock out power to the installation.
Connect the conductors in the power cable to the distribution circuit as follows:
Connect the brown wire to live (one phase).
Connect the blue wire to neutral.
Connect the yellow wire to ground (earth).
Check that all installation is completed and carry out appropriate tests and safety checks before applying power.
Two triangles
signs
Two triangles
signs
Screw