![background image](http://html1.mh-extra.com/html/osram/adb-stagelight-lexpert-profile-l/adb-stagelight-lexpert-profile-l_instruction-manual_1656485018.webp)
LEXPERT PROFILE L
18
8.3 DMX Connection
1. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 5-
pin XLR-plug and plug it in the DMX-output of the last unit.
2. Connect the unit together in a “daisy chain” by XLR plug cable from the output of the unit to the input of the next unit. The cable cannot be branched
or split to a “Y” cable. DMX 512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort
the signal and shut down the system.
3. The DMX output and input connectors are pass-through to maintain the DMX circuit, when one of the units’ power is disconnected.
4. Each lighting unit needs to have a DMX address to receive the data by the controller. The address number is between 0-511 (usually 0 & 1 are equal
to 1).
5. The end of the DMX 512 system should be terminated to reduce signal errors.
6. 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin4, Pin5 not used
1
2
4 5
3
1
2
4 5
3
DMX OUTPUT
DMX INPUT
COMMON
DMX -
DMX +
Not Used
Not Used
5 4
2
1
3
DMX Controller
DMX OUT
7
Summary of Contents for ADB Stagelight LEXPERT PROFILE L