LEXPERT PROFILE L

13

Strobe 

or

Control

. Once the mode has been selected, press the 

ENTER

button to setup, to go back to the functions without any changes press the

MENU 

button again. Hold and press the 

MENU

button for one second or wait for one minute to exit the menu mode.

Fan Speed 

To select the 

Fan Speed

, press the 

ENTER

button to show 

Fan Speed

on the display. Use the 

DOWN

/

UP

button to select the 

Led Fan 

or 

PCB Fan

.

Once the mode has been selected, press the 

ENTER

button to setup, to go back to the functions without any changes press the 

MENU 

button again.

Hold and press the 

MENU

button for one second or wait for one minute to exit the menu mode.

Temperature 

To select the 

Temperature

, press the 

ENTER

button to show the 

Temperature 

on the display. Use the

DOWN

/

UP

button to select the 

Led or  CPU

.

Once the mode has been selected, press the 

ENTER

button to setup, to go back to the functions without any change press the

MENU

button again.

Press and hold the 

MENU

button about one second or wait for one minute to exit the menu mode.

DMX in Rate 

To select the 

DMX in Rate

, press the 

ENTER

button to show 

DMX in Rate

on the display. Use the 

DOWN

/

UP

button to select 

In ms

. Once the mode

has been selected, press the 

ENTER

button to setup, to go back to the functions without any changes press the 

MENU 

button again. Hold and press

the 

MENU

button for one second or wait for one minute to exit the menu mode.

Frequency 

To select the 

Frequency

, press the 

ENTER

button to show 

Frequency

on the display. Use the 

DOWN

/

UP

button to select 

Freq Selec

. Once the mode

has been selected, press the 

ENTER

button to setup, to go back to the functions without any changes press the 

MENU 

button again. Hold and press

the 

MENU

button for one second or wait for one minute to exit the menu mode.

I out 

To select the 

I out

, press the 

ENTER

button to show 

I out

on the display. Use the 

DOWN

/

UP

button to select the 

Unit 

or 

Led

. Once the mode has been

selected, press the 

ENTER

button to setup, to go back to the functions without any changes press the 

MENU 

button again. Hold and press the 

MENU

button for one second or wait for one minute to exit the menu mode.

Hours 

To select the

Hours

, press the 

ENTER

button to show 

I out

on the display. Use the 

DOWN

/

UP

button to select the 

Unit 

or 

Leds

. Once the mode has

been selected, press the 

ENTER

button to setup, to go back to the functions without any changes press the 

MENU 

button again. Hold and press the

MENU

button for one second or wait for one minute to exit the menu mode.

Device ID  

To select the 

Device ID

, press the 

ENTER

button to show 

Device ID

on the display and the display will show the Device ID of the unit. To go back to the func-

tions without any changes press the 

MENU 

button again. Hold and press the 

MENU

button for one second or wait for one minute to exit the menu mode.

Manual CTRL

To select the 

Manual CTRL 

press the 

ENTER

button to confirm, use the 

UP

/

DOWN

button to select

Dimmer, Dimmer Fine 

or

Strobe.

Dimmer 

To select the 

Dimmer

, press the 

ENTER

button to show 

Dimmer

on the display. Use the 

DOWN

/

UP

button to adjust Dimmer from 

to 

255

. Once the

mode has been selected, press the 

ENTER

button to setup, to go back to the functions without any changes press the 

MENU 

button again. Hold and

press the 

MENU

button for one second or wait for one minute to exit the menu mode.

Dimmer Fine

To select the 

Dimmer Fine

, press the 

ENTER

button to show 

Dimmer Fine

on the display. Use the 

DOWN

/

UP

button to adjust Dimmer from 

to 

255

.

Once the mode has been selected, press the 

ENTER

button to setup, to go back to the functions without any changes press the 

MENU 

button again.

Hold and press the 

MENU

button for one second or wait for one minute to exit the menu mode.

Strobe 

To select the 

Strobe

, press the 

ENTER

button to show 

Strobe

on the display. Use the 

DOWN

/

UP

button to adjust Dimmer from 

to 

255

. Once the

mode has been selected, press the 

ENTER

button to setup, to go back to the functions without any changes press the 

MENU 

button again. Hold and

press the 

MENU

button for one second or wait for one minute to exit the menu mode.

Advanced

To select the 

Advanced 

press the 

ENTER

button to confirm, use the 

UP

/

DOWN

button to select

RDM, Data Loss Settings, Slave Mode 

or

Factory

Settings

RDM 

To select the 

RDM

, press the 

ENTER

button to show 

RDM

on the display. Use the 

DOWN

/

UP

button to select the 

On 

or 

Off

. Once the mode has been

selected, press the 

ENTER

button to setup, to go back to the functions without any changes press the 

MENU 

button again. Hold and press the 

MENU

button for one second or wait for one minute to exit the menu mode.

Data Loss Settings 

To select the 

Data Loss Settings

, press the 

ENTER

button to show 

Data Loss Settings

on the display. Use the 

DOWN

/

UP

button to select the 

Black

Out, Last State

or 

Master/Slave

. Once the mode has been selected, press the 

ENTER

button to setup, to go back to the functions without any changes

press the 

MENU 

button again. Hold and press the 

MENU

button for one second or wait for one minute to exit the menu mode.

Summary of Contents for ADB Stagelight LEXPERT PROFILE L

Page 1: ...ons on choosing a ADB product We thank you for your custom Please note that this product as all the others in the rich ADB range has been designed and made with total quality to ensure excellent perfo...

Page 2: ...CTION 2 TECHNICAL SPECIFICATIONS 3 THE UNIT CONSTRUCTION 4 INSTALLATION 5 POWER 6 CONTROL PANEL 7 MAIN FUNCTION 8 HOW TO CONTROL THE UNIT 8 1 DMX Address Setting 8 2 DMX Configuration 8 3 DMX Connecti...

Page 3: ...achige Version des Handbuchs mit Sicherheitshinweisen f r dieses ADB Produkt unter folgendem Link herunterladen www adbstagelight com Rif FIS00X Safety Information LEXPERT PROFILE L C mo obtener tu IN...

Page 4: ...me type spare parts DO NOT touch any wire during operation as high voltage might be causing electric shock To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or m...

Page 5: ...s DMX 512 ArtNET RDM Web page Master Slave and local Zoom Options 15 30 25 50 0 100 linear dimming Variable Strobe Effects Input Voltage AC 100 240V 50 60Hz Power Consumption 345W 230V AC Light Source...

Page 6: ...ngles signs T 3 4 INSTALLATION 2 5 1 3 4 2 1 Lens Module 2 Clip for Gel Holder 3 Bracket 4 Main Body 5 Godo Slot Loosen two screws on two sides of Main Body MB rotate the zoom as the arrow and align i...

Page 7: ...a power cable 14 AWG brown and blue cables installed ready for connection Power cord colors Fig 5 Lock out power to the installation Connect the conductors in the power cable to the distribution circ...

Page 8: ...he next unit and output DMX signal 7 ETHERNET Transfers fixture s information to a main controller 8 Fuse T 6 3A To protect the unit from damage of over current 9 MAINS IN OUT PowerCon connection from...

Page 9: ...on and the display will blink Use the DOWN and UP button to change the mode Once the required mode has been selected press the ENTER button to setup to go back to the functions without any changes pre...

Page 10: ...LEXPERT PROFILE L 10...

Page 11: ...MER CURVES Curve 1 Linear The increase in light intensity appears to be linear as DMX value is increased Curve 2 Quadratic Light intensity control is finer at low levels and coarser at high levels Cur...

Page 12: ...e second or wait for one minute to exit the menu mode Contrast To select the Contrast press the ENTER button to show Inverted on the display Use the DOWN UP button to adjust Contrast from 1 to 30 Once...

Page 13: ...again Hold and press the MENU button for one second or wait for one minute to exit the menu mode Device ID To select the Device ID press the ENTER button to show Device ID on the display and the displ...

Page 14: ...You can operate the unit in five ways 1 Universal DMX controller 2 RDM 3 Master Slave 4 Art Net 5 Manual 8 1 DMX Address Setting If you use a universal DMX controller to control the units you have to...

Page 15: ...0 108 109 110 111 159 160 161 162 207 208 209 210 253 254 255 Open Strobe variable speed Open Pulse Slow closing fast opening variable speed Open Pulse fast closing slow opening variable speed Open Ra...

Page 16: ...Fine 0 100 3 Strobe 000 009 010 057 058 059 060 108 109 110 111 159 160 161 162 207 208 209 210 253 254 255 Open Strobe variable speed Open Pulse Slow closing fast opening variable speed Open Pulse fa...

Page 17: ...ening variable speed Open Pulse fast closing slow opening variable speed Open Random Strobe Slow to Fast Open Random Pulse Slow to Fast Open 4 Control 000 009 010 045 046 080 081 115 116 150 151 235 2...

Page 18: ...or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when...

Page 19: ...e to DMX circuits C Some units don t respond to the easy controller 1 You may have a break in the DMX cabling Check the LED for the response of the master slave mode signal 2 Wrong DMX address in the...

Page 20: ...EN PRELIMINARY 10 2018 Clay Paky S p A Via Pastrengo 3 b 24068 Seriate BG Italy Tel 39 035 654311 Fax 39 035 301876 www claypaky it...

Reviews: