background image

E

N

G

L

IS

H

 

LEXPERT PROFILE L

Zoom 15-30 & Zoom 25-50 

AG2300E41200 - AG2500E41200

Congratulations on choosing a ADB product! We thank you for your custom.

Please note that this product, as all the others in the rich ADB range, has been designed and made with total quality to ensure

excellent performance and best meet your expectations and requirements.

PRELI

MINAR

Y

INSTRUCTION MANUAL

Summary of Contents for ADB Stagelight LEXPERT PROFILE L

Page 1: ...ons on choosing a ADB product We thank you for your custom Please note that this product as all the others in the rich ADB range has been designed and made with total quality to ensure excellent perfo...

Page 2: ...CTION 2 TECHNICAL SPECIFICATIONS 3 THE UNIT CONSTRUCTION 4 INSTALLATION 5 POWER 6 CONTROL PANEL 7 MAIN FUNCTION 8 HOW TO CONTROL THE UNIT 8 1 DMX Address Setting 8 2 DMX Configuration 8 3 DMX Connecti...

Page 3: ...achige Version des Handbuchs mit Sicherheitshinweisen f r dieses ADB Produkt unter folgendem Link herunterladen www adbstagelight com Rif FIS00X Safety Information LEXPERT PROFILE L C mo obtener tu IN...

Page 4: ...me type spare parts DO NOT touch any wire during operation as high voltage might be causing electric shock To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or m...

Page 5: ...s DMX 512 ArtNET RDM Web page Master Slave and local Zoom Options 15 30 25 50 0 100 linear dimming Variable Strobe Effects Input Voltage AC 100 240V 50 60Hz Power Consumption 345W 230V AC Light Source...

Page 6: ...ngles signs T 3 4 INSTALLATION 2 5 1 3 4 2 1 Lens Module 2 Clip for Gel Holder 3 Bracket 4 Main Body 5 Godo Slot Loosen two screws on two sides of Main Body MB rotate the zoom as the arrow and align i...

Page 7: ...a power cable 14 AWG brown and blue cables installed ready for connection Power cord colors Fig 5 Lock out power to the installation Connect the conductors in the power cable to the distribution circ...

Page 8: ...he next unit and output DMX signal 7 ETHERNET Transfers fixture s information to a main controller 8 Fuse T 6 3A To protect the unit from damage of over current 9 MAINS IN OUT PowerCon connection from...

Page 9: ...on and the display will blink Use the DOWN and UP button to change the mode Once the required mode has been selected press the ENTER button to setup to go back to the functions without any changes pre...

Page 10: ...LEXPERT PROFILE L 10...

Page 11: ...MER CURVES Curve 1 Linear The increase in light intensity appears to be linear as DMX value is increased Curve 2 Quadratic Light intensity control is finer at low levels and coarser at high levels Cur...

Page 12: ...e second or wait for one minute to exit the menu mode Contrast To select the Contrast press the ENTER button to show Inverted on the display Use the DOWN UP button to adjust Contrast from 1 to 30 Once...

Page 13: ...again Hold and press the MENU button for one second or wait for one minute to exit the menu mode Device ID To select the Device ID press the ENTER button to show Device ID on the display and the displ...

Page 14: ...You can operate the unit in five ways 1 Universal DMX controller 2 RDM 3 Master Slave 4 Art Net 5 Manual 8 1 DMX Address Setting If you use a universal DMX controller to control the units you have to...

Page 15: ...0 108 109 110 111 159 160 161 162 207 208 209 210 253 254 255 Open Strobe variable speed Open Pulse Slow closing fast opening variable speed Open Pulse fast closing slow opening variable speed Open Ra...

Page 16: ...Fine 0 100 3 Strobe 000 009 010 057 058 059 060 108 109 110 111 159 160 161 162 207 208 209 210 253 254 255 Open Strobe variable speed Open Pulse Slow closing fast opening variable speed Open Pulse fa...

Page 17: ...ening variable speed Open Pulse fast closing slow opening variable speed Open Random Strobe Slow to Fast Open Random Pulse Slow to Fast Open 4 Control 000 009 010 045 046 080 081 115 116 150 151 235 2...

Page 18: ...or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input connectors are pass through to maintain the DMX circuit when...

Page 19: ...e to DMX circuits C Some units don t respond to the easy controller 1 You may have a break in the DMX cabling Check the LED for the response of the master slave mode signal 2 Wrong DMX address in the...

Page 20: ...EN PRELIMINARY 10 2018 Clay Paky S p A Via Pastrengo 3 b 24068 Seriate BG Italy Tel 39 035 654311 Fax 39 035 301876 www claypaky it...

Reviews: