background image

Air Overlay Mattress User Guide

9

Waste disposal

The materials used to manufacture the OSKA 

SeriesC Air cushion do not cause any danger to 

the environment. They may be disposed of with 

the household waste.
The pump control unit is considered as electrical 

equipment waste. Please contact the proper waste 

disposal officials.

Warranty

Your OSKA product comes with a 1 year parts 

and labour warranty.
The warranty is based on statutory regulations. 

The warranty does not apply if the goods supplied 

by OSKA are processed, handled or modified by 

other parties without prior consent from OSKA 

or if these operating instructions are not followed.
For medical devices as understood by the EU - 

Directive 93/94, whose usage (also operations) 

is subject to regular service and maintenance, 

a warranty can be offered only if the service 

intervals prescribed by OSKA are adhered to. 
If during inspection it is found that damages 

are due to wear and tear or are not subject to 

warranty, then OSKA are empowered to claim the 

expenses (inspection, transport costs etc) from 

the client.
The use of parts or individual components of 

other systems or products or combinations 

thereof are not permissible. 
Warranty claims become invalid should any 

damage result from this kind of conduct and 

therefore remain the responsibility of the user/

owner.

WARNING!

For private non-professional operators. In the 

case of system failure please check:
01.   Is there sufficient power supply?
02.   Is the unit turned on?
03.   Is the power cord connected properly 

and is the power plug inserted 

correctly?

04.   Is the mattress connection tube 

connected properly?

If all these primary checks have been carried 

out and the system continues not to function 

then you must contact the responsible 

supplier or user who is authorised to effect 

the maintenance and/or repair of this 

equipment.
Never attempt to repair the system yourself. 

Fuses may only be exchanged by qualified 

and authorised personnel.

Safety

In the interest of your safety please be informed 

that the OSKA SeriesC Air is certified in 

accordance to the following regulations:
Testing for DIN EN 60601-1 
CPR - emergency valve 
ISO 13485

For your safety and the safety of those around 
you, please adhere to all safety and warning as 
detailed in this manual.

WARNING!

You MUST be aware of the susceptibility of 

this air mattress to the incidence of fire. In 

the case of a fire the unavoidable release of 

air acts as a fan effect to assist the flames.

You must avoid smoking at all times in the 

immediate vicinity of this product. Other 

hazards can include: The use of petroleum 

based creams and gels such as Vaseline etc. 

The manufacturer of this product takes no 

responsibility for actions that are in breach 

of this fire hazard warning which includes 

all environments: Hospitals, care homes and 

private/domestic users.

Summary of Contents for SeriesC Air

Page 1: ...User Guide SeriesC Air ...

Page 2: ... use on a chair within home or care environment with power source nearby to ensure that comfort and relief levels are maintained The system consists of a control unit featuring a membrane pump and a cushion with 6 air cells arranged in a transverse manner The entire cell unit is encased in a cradle of visco foam The bielastic top cover and PVC outer base cover ensure stability comfort and infectio...

Page 3: ...ns and the products Press the alarm reset button see 4 to mute the audible alarm its indicator will flash 1A Operation 01 When the pressure reaches full inflation within approximately 5 minutes the normal pressure indicator will illuminate and the low pressure indicator will turn off 02 Turn the pressure dial see 5 to set a comfortable pressure level from 40 110kg according to the approximate weig...

Page 4: ...t the appliance to the nearest mains socket and ensure that the power indicator light is on Contact OSKA Service The pump appears to be on running but is not reaching the desired pressure setting The hoses are connected correctly Disconnect the hoses and re connect them in to the outlet connectors on the side of the pump Contact OSKA Service The pump is running but is not inflating the cushion The...

Page 5: ...e user owner WARNING For private non professional operators In the case of system failure please check 01 Is there sufficient power supply 02 Is the unit turned on 03 Is the power cord connected properly and is the power plug inserted correctly 04 Is the mattress connection tube connected properly If all these primary checks have been carried out and the system continues not to function then you m...

Page 6: ...Air Overlay Mattress User Guide Edward House 5 Penner Road Havant PO9 1QZ 0845 381 0600 ask oska uk com oska uk com Pressure Care Experts ...

Reviews: