3.4 Mechanical Assembly
The items needed in mechanical assembly
are packed in the box containing the cross
piece.
For checking the distance of the coil panels
there is a pasteboard gauge in the cross
piece box.
Ref
Part
Pcs
1............ TX panel ......................... 1
2............ RX panel ........................ 1
3............ Cross piece .................... 1
5............ Mounting screws ............. 8
Anti-skid pads ................. 4
Allen key ......................... 1
The following parts illustrated in picture are
integrated into coil cross piece, but they
must be considered in assembly:
Ref
Part
Pcs
4............ Display and keypad ........ 1
•
First define the sides of the coil panels if you have side-by-side operation.
•
Both panels have zone display on both edges. Zone displays are also used for traffic
light function.
•
Lay the coil panels on the floor.
•
Install the cross piece with display and keypad towards the exit side.
•
Take cable assembly (and AC jumper cable) out of the coil panel and put it into the
cross piece.
•
Place the cross piece to the holes in the coil panel and fasten using the mounting
screws.
•
Repeat with the other panel.
•
Pull AC jumper cable out of boot and connect mains power cord to it. Connectors can
be inserted back into the boot to prevent accidental disconnection and for protection
against weather.
•
Do the final tightening of the screws after lifting the unit to ensure that the panels are
parallel.
CAUTION
While assembled three persons are recommended for safe lifting and lowering of the
equipment.