Charger Error Codes
Code
Description
Solution
E-0-0-1
E-0-2-1
Battery high voltage
Check the battery voltage and cable connections. Check battery size and
condition. This error will automatically clear once the condition has been
corrected.
E-0-0-2
E-0-2-2
Battery low voltage
Check the battery voltage and cable connections. Check battery size and
condition. This error will automatically clear once the condition has been
corrected.
E-0-0-3
Charge timeout caused by battery pack not
reaching required voltage within safe time
limit.
Possible causes: Charger output reduced due to high temperatures, poor battery health, very
deeply discharged battery and /or poorly connected battery. Possible solutions: Operate at
lower ambient temperature. Replace battery pack. Check DC connections. This error will
automatically clear once the charger is reset by cycling DC.
E-0-0-4
Battery could not meet minimum voltage
Check for shorted or damaged cells. Replace battery pack. Check DC connections. This
error will automatically clear once the charger is reset by cycling DC.
E-0-0-7
Battery amp hour limit exceeded
Possible causes include poor battery health, very deeply discharged battery, poorly con
-
nected battery, and / or high parasitic loads on battery while charging. Possible solutions:
Replace battery pack. Check DC connections. Disconnect parasitic loads. This error will
automatically clear once the charger is reset by cycling DC.