SECTION 5: MAINTENANCE
Manual # 99905932 (February 2016)
PAGE - 27
®
IOWA MOLD TOOLING CO., INC.
(641) 923-3711 • www.imt.com
Figure 5-2: Fuse and Breaker Locations
KEY
DESCRIPTION
A
FUSE (10A)
B
CIRCUIT BREAKER
(30A for 12V),
(20A for 24V)
C
RELAY (x3)
D
FUSE (14A)
E
BACKSIDE OF INSTRUMENT
PANEL (REFERENCE)
F
LIFTING BAIL (REFERENCE)
E
A
B
C
D
3. The reset button should pop out
and the compressor should
stop, indicating that the gauge
shutdown contact is working.
4. Switch compressor OFF and
press reset button to reactivate
shutdown system.
5.4.2.2 PRESSURE RELIEF VALVE
Refer to
Section 7.2
for valve location.
Although the pressure relief valve has a
reset ring at the cap,
DO NOT
test the
pressure relief valve by pulling on the reset
ring. The pressure relief valve requires no
safety testing.
5.4.3 LONG TERM STORAGE
Parts can wear out over time, regardless of
the degree of usage. If storing the IMT
CAS80R unit for long periods of time,
depressurize the air tank and open the drain
valve on the tank. Cover with a tarp or plastic
to prevent the accumulation of dust, but
leave the bottom open for air circulation.
Whenever possible, store in a sheltered area
to minimize exposure to the elements.
KEY
DESCRIPTION
A
GAUGE BEZEL
B
GAUGE TEST CONTACT
C
INSULATED SCREW DRIVER
D
SAFETY TEST CONTACT
Reset button should pop out, and compressor
should stop.
Figure 5-3: Safety Shutdown Test
A
B
D