SECTION 3: INSTALLATION
CAS80R
PAGE - 14
Manual # 99905932 (February 2016)
IOWA MOLD TOOLING CO., INC.
(641) 923-3711 • www.imt.com
®
exits through vents in the upper sides and
the rear.
3.10.2 CLEARANCE
Refer to
Figure 3-4
. Ensure that adequate
surrounding clearance exists to allow for the
canopy shroud to be re-positioned or
removed for service access.
3.10.3 MOUNTING
Mounting surface or support should be
adequate for the weight of the machine (375
lbs.), and should be level for normal
operation. Mounting holes are located in the
frame footing for four (4) 1/2” hold down
bolts.
3.10.4 SERVICE CONNECTIONS
Refer to
Figure 3-4
. Service connections are
conveniently grouped at the lower rear
section of the unit in the base frame.
3.10.5 ELECTRICAL CONNECTIONS
This system is offered with either 12V DC or
24V DC negative ground.
Refer to
Section
7.10, Wiring Diagram.
3.10.6 HYDRAULIC SUPPLY CIRCUIT
It is recommended that the compressor unit
possesses a separate pump/flow/return
hydraulic
circuit
to
other
hydraulic
equipment. This is to prevent the possibility
of pressure/flow drops that may occur if
other hydraulically-powered equipment is
activated during compressor operation,
which may in turn, cause the compressor to
stall out. Alternatively, use of a diverter valve
will permit hydraulics to power different
equipment selectively.
3.10.7 ROUTING
Refer
to
Section
7.11,
Schematic
Hydraulic Oil Flow
. Ensure that all supply
hoses and electrical wiring are correctly
specified, adequately supported, and do not
touch or rest on any sharp edges. Wiring
should be protected with split loom to
prevent corrosion, and consequently, loss
due to down time.
Wire #1
(10 gauge)
Battery (+) VDC supply
Wire #3
(12 gauge)
Ignition (+) VDC supply
Wire #2
(10 gauge)
Fan Circuit
Wire #4
(10 gauge)
Ground