Adjustment of temperature control:

Water temperature

 

-

 

+

 

Solar temperature

 

-

 

+

 

The electronic temperature control and the temperature
sensor have been matched factory-provided. If one of the
sensors is being exchanged or the sensor leads is being
lengthened, you have to carry out a new adjustment with the
potentiometers in the control unit, as necessary. A clockwise
turning of the potentiometer for the water temperature sensor
will cause an increase of the displayed water temperature. If
the potentiometer for the solar sensor is turned clockwise, an
increased collector temperature will be displayed. Since the
solar temperature control only works properly with precisely
adjusted sensors, this adjustment should only be carried out
by a trained service technician.

Fuses:

T2A

Inside the housing the electronic control is protected
by a 2A micro-fuse on the circuit board. The short-
circuit protection for the filter pump has to be
ensured by customer provided pre-fuses of max.
16A.

Electronic motor protection:

22

 

23

 

30

 

31

 

32

 

33

 

Heating

 

Motor-

 

Water

 

Sun

 

protection 

0

 

8A

 

The three-phase-current filter pump is protected against
damages caused by overload by an electronic motor protection.
For this the motor protection has to be adjusted to the nominal
current of the filter pump (see type plate of the pump). The
adjusting regulator for the motor protection is placed in the
clamping box, to protect it against inadvertent adjusting. If the
nominal current of the filter pump is not known, the motor
protection can be adjusted according to the following process:
1. Turn adjusting screw of the motor protection to the right stop.
2. Switch on pump
3. Turn adjusting screw slowly anti-clockwise as long till the

motor protection is triggered and the error signal 

motor- 

protect.

will appear.

4. Turn adjusting screw clockwise by some angular degrees

(approx. 10%).

5. Confirm error signal with the   key – the filter pump can be

switched on again.

Summary of Contents for 3100000430

Page 1: ...TRONIK 10 enable an upgrade of the filter control to an automatic filter and backwash control By using additional connecting terminals it is possible to connect accessory devices such as dosing equipm...

Page 2: ...housing it is absolutely necessary to switch the device to zero potential Electrical connection The electrical connection as well as adjustment and service work may only be carried out by accredited...

Page 3: ...ng PC 25 max 4A 22 23 heating 230V L1 N PC 25 heating 22 23 flow monitor L1 N or STB 400V L1 L2 L3 PC 25 U2 N 6 2 3 U3 actuator 230V Solar The floating relay contact between the clamps 22 and 23 can b...

Page 4: ...esult in an immediate switching off of the filter pump the dosing equipment and the heating The closing of one of the contacts between clamps 2 and 4 or 11 and 12 will cause a forced switch on of the...

Page 5: ...ect operating mode Pilot light operating mode Set time Interrogate soalr temperature Pilot light solar operation Pilot light heating Heating ON OFF LCD display Adjustment buttons LCD display 23 4 14 4...

Page 6: ...by the colour of the light green The temperature control is running the selected water temperature has been reached yellow The heating is running the selected temperature has not been reached yet red...

Page 7: ...ow be set 3 Press again the display will show 0 00 OFF 1 4 By pressing the and keys the requested off period can now be set 5 Press key again the display will show ON 2 6 Additional switching times ca...

Page 8: ...fuse on the circuit board The short circuit protection for the filter pump has to be ensured by customer provided pre fuses of max 16A Electronic motor protection 22 23 30 31 32 33 Heating Motor Water...

Page 9: ...nput 0 l Mains230V 1 N PE 11 12 13 14 4 7 6 5 8 U1 N N L1 Solenoid valve 230V Water level 3 N PE EUROTRONIK 10 Motor protect contact Filterpump temperature probe heating pump W Mains 400V chemical con...

Page 10: ...Operating Instructions PC 25 page 10 10...

Reviews: