Operating Instructions PC-25 page 2 (10)
Technical Specifications:
Dimensions:
220mm x 219mm x
100mm
Operating voltage:
400V/50Hz
Power consumption of the control:
ca.10VA
Breaking capacity:
Pump:
max. 3,0 kW (AC3)
Heating:
max. 230V/4A
Dosing
equipment:
max. 230V/4A
Protection type:
IP 40
Installation:
The control unit has to be installed humidity protected, depending on its protection
type. The power supply of the device has to be carried out via an all-pole(?) main
switch with a contact opening width of at least 3mm and an earth leakage circuit
breaker with I
FN
≤
30mA.
Before opening the housing it is absolutely necessary to
switch the device to zero potential.
Electrical connection:
The electrical connection as well as adjustment- and service work may only be
carried out by accredited electrical specialists! The enclosed connecting
diagrams and the corresponding prevailing safety regulations must be
observed.
Mains supply for use of a 400V-three-phase current pump:
Pool-Control-25
winding
protection
3
M
W1
V1
U1
L3
L2
L1
N
WSK
FI-switch
max. B16A
pre-fusing
400V max. 8A
filter pump
net 3/N/
400/230V 50Hz
25A/0,03A
The factory-provided inserted bridge between the two clamps called WSK, has to be
removed, if connected with a pump with winding protective contact. If no connection
is carried out, it has to be remained screwed in. The clamps drive mains voltage!