background image

 
 
 
 
 
 
 
 
 
 
 
  
 
 
 
 
 
 

OPERATOR MANUAL 

 
 
 
 
 

OSD2600P SERIES 

MANAGED 

ETHERNET SWITCH 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 2600P series

Page 1: ...OPERATOR MANUAL OSD2600P SERIES MANAGED ETHERNET SWITCH ...

Page 2: ......

Page 3: ...IONS 14 3 2 2 POWER SUPPLY CONNECTIONS 15 3 2 3 LED INDICATORS 15 3 2 4 WEB BASED BROWSER INTERFACE 15 3 2 5 ADMINISTRATION CONSOLE VIA RS 232 SERIAL PORT CLI 15 3 2 6 EXTERNAL SNMP BASED NETWORK MANAGEMENT APPLICATION 15 3 2 7 ALARMS FOR POWER FAILURE 16 3 3 OSD2600P OPERATION 17 3 3 1 CABLE CONNECTIONS 17 4 SWITCH MANAGEMENT 18 4 1 MANAGEMENT ACCESS OVERVIEW 18 4 2 ADMINISTRATION CONSOLE CLI 18 ...

Page 4: ... 802 1X 141 7 11 OTHER PROTOCOLS 145 8 APPENDIX A 154 9 MAINTENANCE 155 9 1 INTRODUCTION 155 9 2 EXTERNAL INSPECTION 155 9 3 ROUTINE MAINTENANCE 155 10 WARRANTY 156 10 1 WARRANTY PERIOD 156 10 2 REPAIRS 156 10 2 1 WARRANTY REPAIRS 156 10 2 2 OUT OF WARRANTY REPAIRS 156 10 2 3 SITE REPAIRS 156 10 2 4 EXCLUSIONS 156 FIGURE 1 OSD2600P FRONT AND REAR PANELS 5 FIGURE 2 CLI SETUP 7 FIGURE 3 CLI SETUP 8 ...

Page 5: ...lid network connection established Flashing Transmitting or receiving data ACT stands for ACTIVITY 10 100 Steady Connecting at 100Mbps speed Off Connecting at 10Mbps speed PoE Steady Power Device PD is connected Off Power Device PD is disconnected 100Base FX BX Link ACT Steady A valid network connection established Flashing Transmitting or receiving data ACT stands for ACTIVITY 100 Steady Connecti...

Page 6: ... 1000Mbps full duplex 10 100Mbps full half duplex Auto MDI MDIX 100Base FX Multi mode SC or ST type Single mode SC or ST type 100Base BX WDM Single mode SC type 1000Base SX LX Multi mode SC type Single mode SC type 1000Base BX WDM Single mode SC type Provides up to two combo Gigabit ports Store and forward mechanism Full wire speed forwarding rate Alarms for port and power failure by relay output ...

Page 7: ...And the switch_a prompt will show on the screen FIGURE 2 CLI SETUP Logon to Privileged Exec Mode Enable Mode At the switch_a prompt just type in enable and press Enter to logon to Privileged Exec Mode or Enable Mode And the switch_a prompt will show on the screen Logon to Configure Mode Configure Terminal Mode At the switch_a prompt just type in configure terminal and press Enter to logon to Confi...

Page 8: ...TION Login the switch Specify the default IP address 192 168 1 10 of the switch in the web browser A login window will be shown as below FIGURE 4 WEB CONFIGURATION 1 Enter the factory default login ID root Enter the factory default password no password Then click on the Login button to log on to the switch ...

Page 9: ...OPTICAL SYSTEMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 9 FIGURE 5 WEB CONFIGURATION 2 ...

Page 10: ...70km on singlemode fiber 1550nm It normally requires two fibers per port but is optionally available for one fiber operation A major benefit of the OSD2600P is its reliable and consistent performance over the 40 C to 75 C temperature range that allows it to be used in uncontrolled environments such as roadside cabinets mine sites and factories 2 1 3 APPLICATIONS Any network utilizing a mix of copp...

Page 11: ...OPTICAL SYSTEMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 11 2 2 TYPICAL CONFIGURATION Figure 6 below indicates a possible set up for an OSD2600P system FIGURE 6 OSD2600P TYPICAL CONFIGURATION ...

Page 12: ... full duplex flow control Transmitter Wavelength 1310nm 30nm Transmit Optical Power 10dBm to 4dBm 6dBm and 0dBm 1310nm and 1550nm are optional Receiver Sensitivity 21dBm Standard Optical Link Budget 11dB 550m on multimode fiber 1310nm Fiber bandwidth limited 20km on singlemode fiber 1310nm 70km on singlemode fiber 1550nm Optional Optical Link Budget 23dB 100km on singlemode fiber with optional 155...

Page 13: ... fixed copper ports and two optical ports on the front panel The rear panel consists of a terminal block connector Each section will be described further throughout this manual FIGURE 7 OSD2600P FRONT AND REAR PANELS 2 4 1 OSD2600P DIMENSIONS The OSD2600P is designed to be mounted onto a 19 rack unit occupying 1RU space or can be free standing on an even surface 442 44 ...

Page 14: ...uct may cause radio interference in which case the user may be required to take adequate measures OPTICAL OUTPUT OPERATION WARNING Laser Safety Class 1 Laser Product per IEC EN 60825 1 20011 standard Class 1 The OSD2600 is a Class 1 laser product PRECAUTIONS All service personnel should be provided training as to the hazards of direct viewing of laser radiation and of the precautionary measures du...

Page 15: ... PD is connected Off Power Device PD is disconnected 100Base FX BX Link ACT Steady A valid network connection established Flashing Transmitting or receiving data ACT stands for ACTIVITY 100 Steady Connecting at 100Mbps speed Off No connection 10 100 1000Base TX 1000Base SX LX BX Link ACT Steady A valid network connection established Flashing Transmitting or receiving data ACT stands for ACTIVITY 1...

Page 16: ...o send a signal for power failure detection Power Input Assignment Power2 47 55VDC Terminal Block Power Ground Power1 47 55VDC Power Ground Earth Ground Relay Output Rating 1A 250VAC Relay Alarm Assignment FAULT Warning signal disable for following The relay contact closes if Power1 and Power2 are both failed Special Note The relay output is normal open position when there is no power to the switc...

Page 17: ...ir UTP STP Cat 5 100m 100Base FX ST SC 200 Mbps MMF 62 5µm 2km 100Base FX ST SC 200 Mbps SMF 10µm 20 40 75 100km 100Base BX SC 200 Mbps MMF 62 5µm 2 5km 100Base BX SC 200 Mbps SMF 10µm 20 40km 1000Base SX SC 2000 Mbps MMF 62 5µm 220m 2km 1000Base SX SC 2000 Mbps MMF 50µm 550m 1000Base LX SC 2000 Mbps SMF 10µm 10 20 50km 1000Base BX SC 2000 Mbps SMF 10µm 20 40km Optical 1000Base SX Duplex LC 2000 M...

Page 18: ...tion console is an internal character oriented Command Line Interface CLI for performing system administration such as displaying statistics or changing option settings Using this method you can view the administration console from a terminal personal computer Apple Macintosh or workstation connected to the switch s console port 4 2 1 DIRECT ACCESS Direct access to the administration console is ac...

Page 19: ... terminal protocols such as Telnet A virtual terminal protocol is a software program such as Telnet that allows you to establish a management session from a Macintosh a PC or a UNIX workstation Because Telnet runs over TCP IP you must have at least one IP address configured on the switch before you can establish access to it with a virtual terminal protocol Note Terminal emulation is different fro...

Page 20: ...witch provides RMON capabilities that allow network administrators to set parameters and view statistical counters defined in MIB II Bridge MIB and RMON MIB RMON activities are performed at a Network Management Station running an SNMP network management application with graphical user interface 5 2 SNMP AGENT AND MIB 2 RFC 1213 The SNMP Agent running on the switch manager CPU is responsible for Re...

Page 21: ...low a threshold RMON Event Group allows a network administrator to define actions based on alarms SNMP Traps are generated when RMON Alarms are triggered The action taken in the Network Management Station depends on the specific network management application 5 3 2 BRIDGE GROUPS SUPPORTED The switch supports the following four groups of Bridge MIB RFC 1493 The dot1dBase Group a mandatory group tha...

Page 22: ...describes how to configure the switch using its web based browser interface 6 1 LOGGING ON TO THE SWITCH SWITCH IP ADDRESS In your web browser specify the IP address of the switch Default IP address is 192 168 1 10 LOGIN Enter the factory default login ID root PASSWORD Enter the factory default password no password Or enter a user defined password if you followed the instructions later and changed...

Page 23: ...Reboot Logout PORT Configuration Port Status Rate Control RMON Statistics Per Port VLAN Activities SWITCHING Bridging Static MAC Entry Port Mirroring TRUNKING Port Trunking STP RING Global Configuration RSTP Port Setting MSTP Properties MSTP Instance Setting MSTP Port Setting Ring Setting VLAN VLAN Mode Setting 802 1Q VLAN Setting 802 1Q Port Setting Port Based VLAN QOS Global Configuration 802 1p...

Page 24: ...CAL SYSTEMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 24 6 3 SYSTEM SYSTEM INFORMATION The System name Firmware version MAC address Default gateway VLAN ID IP Address and IP Subnet Mask of Switch ...

Page 25: ...ank or replace the current system name with a new one 2 Updating setting Click Updating setting button to update your settings 3 Password Click in Password text box Type a password 4 Retype Password Click in Retype Password text box Type the same password in Password text box again to verify it 5 Updating setting Click Updating setting button to update your settings ...

Page 26: ... subnet mask are changed 5 Default Gateway Click Default Gateway drop down menu to choose Disable or Enable from the Default Gateway drop down list to disable or enable Default Gateway Setting for the switch 6 Click the text box and type a new address to change the Default Gateway 7 DNS Server Click DNS Server drop down menu to choose Disable or Enable from the DNS Server drop down list to disable...

Page 27: ...will be backed up 7 Click in FILE text box and type the name of the file that will be backed up 8 Click Backup button to backup the file to the TFTP server 9 Save Configuration Click Save Configuration button to save your configuration settings 10 Restore Default Click Restore Default button to restore the default settings of the switch 11 Auto save Click Auto save drop down menu to choose Disable...

Page 28: ...h 2 TFTP server IP Click in TFTP server IP text box and type the TFTP server IP address from where the file will be obtained 3 Upgrade Click upgrade button to upgrade firmware to the switch Please follow the message on the screen during the firmware upgrade process Do not turn off the power or perform other functions during this period of time Reboot the switch after completing the upgrade process...

Page 29: ...EMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 29 Please follow the message on the screen during the firmware upgrade process Do not turn off the power or perform other functions during this period of time ...

Page 30: ...OPTICAL SYSTEMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 30 Firmware has been upgraded successfully to the switch Reboot the switch after completing the upgrade process ...

Page 31: ...op down menu to choose fe1 fe16 ge1 ge2 or Power1 Power3 from the Name drop down list 2 Trigger Enabled Click Trigger Enabled drop down menu to choose YES or NO from the Trigger Enabled drop down list to enable or disable Trigger 3 Update Setting Click Update Setting button to update settings to the switch ...

Page 32: ...OPTICAL SYSTEMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 32 REBOOT Reboot Click Reboot button to restart the switch ...

Page 33: ...OPTICAL SYSTEMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 33 LOGOUT Logout Click Logout button to logout of the switch ...

Page 34: ...op down list to disable or enable Admin Setting for the port Speed Click Speed drop down menu to change the line speed and duplex settings from the Speed drop down list for the port Flow control Click Flow control drop down menu to choose Disable or Enable from the Flow control drop down list to disable or enable Flow control for the port Submit Click Submit button when you finished configurations...

Page 35: ...OPTICAL SYSTEMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 35 PORT STATUS View the Link Status Speed Duplex and Flow control status for all ports ...

Page 36: ...s 128kbps 192kbps 1792kbps 2Mbps 3Mbps 4Mbps 100Mbps 104Mbps 112Mbps 120Mbps 1000Mbps Note M 1024k 2 Egress Click in Egress text box and type a new Rate to change the Egress Rate Control for the port Rate Values 64kbps 128kbps 192kbps 1792kbps 2Mbps 3Mbps 4Mbps 100Mbps 104Mbps 112Mbps 120Mbps 1000Mbps Note M 1024k 3 Update setting Click Update setting button when you finished these Rate Control se...

Page 37: ...OPTICAL SYSTEMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 37 RMON STATISTICS Click Port 1 Port 18 to view corresponding RMON Statistics ...

Page 38: ...OPTICAL SYSTEMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 38 PER PORT VLAN ACTIVITIES Click Port 1 Port 18 to view corresponding VLAN activities ...

Page 39: ...ging Time settings 3 Threshold level 0 1 100 Click in Level text box and type a decimal number for the port Need to choose Broadcast and or DFL Multicast from Storm control enabled type for the port DLF Destination Lookup Failure 4 Storm control enabled type Choose Broadcast and or DLF Multicast from Storm control enabled type for the port 5 Update Setting Click Update Setting button when you fini...

Page 40: ...from the Delete MAC address drop down list to be deleted from port 4 Submit Click Submit button when you finished Static MAC Entry Forward settings Static MAC Entry Discard 1 Add MAC address Click in Add MAC address text box and type a MAC address to be discarded for the VLAN 2 VLAN ID VLAN ID Click VLAN ID drop down menu and choose a VLAN ID from the VLAN ID drop down list 3 Delete MAC address Cl...

Page 41: ...rom port from Port 1 Port 18 2 Mirror To Click Mirror To drop down menu to Choose Mirror To port Port 1 Port 18 from Mirror To drop down list 3 Mirror Mode Click Mirror Mode drop down menu to Choose Tx Rx Tx or Rx from Mirror Mode drop down list 4 Submit Click Submit button when you finished Port Mirroring settings ...

Page 42: ...ssification to enable or disable this port to provide power to PD according to classification of maximum power range used by PD 3 Fixed Power Limit W First uncheck Power Limit by Classification to disable this port to provide power to PD according to classification of maximum power range used by PD Then click in Fixed Power Limit W text box and type a new fixed power limit for this port to provide...

Page 43: ...ng click Enable Mode drop down menu to choose Scheduling from Enable Mode drop down list to schedule this port to discover Powered Device PD connected to this port PoE Per Port Setting 1 Port Click Port drop down menu to choose a port from Port drop down list and configure PoE scheduling to this port 2 Submit Click Submit button when you finished PoE Scheduling for this port ...

Page 44: ...ORT TRUNKING Static Channel Group 1 Trunk 1 Click Port 1 Port 16 to assign ports to Trunk 1 Maximum 4 ports per Trunk GE Trunking 1 Trunk 3 Check Static or Disable to enable or disable Trunk 3 for Gigabit Ethernet ports Submit Click Submit button when you finished Port Trunking settings ...

Page 45: ...ty text box and type a decimal number between 0 and 61440 3 Hello Time sec 1 9 Click in Hello Time text box and type a decimal number between 1 and 9 4 Max Age sec 6 28 Click in Max Age text box and type a decimal number between 6 and 28 5 Forward Delay sec 4 30 Click in Forward Delay text box and type a decimal number between 4 and 30 6 STP Version Click STP Version drop down menu to choose MSTP ...

Page 46: ...ting is 128 4 Admin Path Cost Click in Admin Path Cost text box and enter a value between 0 and 2000000 to set the Admin Path Cost for the port 0 auto Setting 0 for the Admin Path Cost will automatically set the speed for forwarding packets to the port for optimal efficiency Default port cost 100Mbps port 200000 Gigabit port 20000 5 Point to Point Link Click Point to Point Link drop down menu to C...

Page 47: ...OPTICAL SYSTEMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 47 ...

Page 48: ...MST bridge is a region by itself unless specifically added to one 3 Revision Level Click in Revision Level text box to specify the number for configuration information The default value of revision number is 0 4 Max Hops Click in Max Hops text box to specify the maximum allowed hops for BPDU in an MST region This parameter is used by all the instances of the MST Specifying the max hops for a BPDU ...

Page 49: ...D 4 Update setting Click Update setting button when you finished VLAN Instance Configuration Included VLANs 1 Instance ID Click Instance ID drop down menu to choose instance ID from Instance ID drop down list 2 Included VLAN Click Included VLAN drop down menu to choose VLAN from Included VLAN drop down list Instance Setting 1 Bridge Priority 0 61440 Click in Bridge Priority text box to set the bri...

Page 50: ...OPTICAL SYSTEMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 50 ...

Page 51: ...t drop down list 2 Priority Granularity 16 Click in Priority text box to set the port priority for a bridge group The Multiple Spanning Tree Protocol uses port priority as a tiebreaker to determine which port should forward frames for a particular instance on a LAN or which port should be the root port for an instance A lower value implies a better priority In the case of the same priority the int...

Page 52: ...e or disable Ring state 2 Update setting Click Update setting button when you finished Ring state setting Set ring port 1 Ring port 1 Click Ring port 1 drop down menu to choose Ring port 1 from Ring port 1 drop down list 2 Ring port 2 Click Ring port 2 drop down menu to choose Ring port 2 from Ring port 2 drop down list 3 Update setting Click Update setting button when you finished Set ring port ...

Page 53: ...UAL PAGE 53 6 8 VLAN VLAN MODE SETTING 1 VLAN Mode Setting Click VLAN Mode Setting drop down menu to Choose Tag based VLAN or Port based VLAN from VLAN Mode Setting drop down list 2 Update Setting Click Update Setting button when you finished VLAN Mode Setting ...

Page 54: ...2 4094 Click in the VLAN ID textbox and specify a new VLAN ID number from 2 4094 4 VLAN Name Click in the VLAN Name textbox and type a name for this newly created VLAN Add port to or delete port from VLAN 1 VLAN Member Choose the port to be added to or deleted from the VLAN 2 Tag or Untag Click Tag or Untag drop down menu to Choose Tag or Untag from Tag or Untag drop down list for a Hybrid port 3 ...

Page 55: ...VLAN setting Click VLAN setting The VLAN Setting window appears 2 Delete VLAN Click Delete VLAN button 3 Select a VLAN ID Click Select a VLAN ID drop down menu from Select a VLAN ID drop down list to choose the VLAN to be deleted Submit Click Submit button when you finished VLAN setting ...

Page 56: ...de drop down menu to Choose Access Trunk or Hybrid from Mode drop down list for the port The port will be Tag port if you choose Trunk Mode for the port And the port will be Tag or Untag port if you choose Hybrid Mode for the port 3 PVID Click in the PVID textbox and specify a new PVID number for the port 4 Update Setting Click Update Setting button when you finished VLAN Port Setting ...

Page 57: ...the port to be added to or deleted from the VLAN 2 Select all Click select all button to choose Port 1 Port 18 all to be added to the VLAN 3 Delete all Click delete all button to choose Port 1 Port 18 all to be deleted from the VLAN 4 Submit Click Submit button when you finished Port Based VLAN setting ...

Page 58: ...ble a routed port to trust the DSCP Differentiated Service Code Point labels of all traffic received on that port 3 Policy Choose Strict Priority Queue3 WRR Queue0 2 or WRR Queue0 3 A strict priority queue is always emptied first The queues that are used in the WRR Weighted Round Robin are emptied in a round robin fashion and you can configure the weight for each queue 4 Weighted Round Robin Click...

Page 59: ...ID 10112303 OSD2600 OPERATOR MANUAL PAGE 59 802 1P PRIORITY 1 Priority Click Priority drop down menu from Priority drop down list to choose 0 3 for VLAN Priority 0 7 2 Submit Click Submit button when you finished 802 1p priority ...

Page 60: ... DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 60 DSCP 1 Priority Click Priority drop down menu from Priority drop down list to choose 0 3 for DSCP Priority 0 63 Submit Click Submit button when you finished DSCP ...

Page 61: ...tion for SNMP 4 Contact Click in the Contact textbox and specify a new contact for SNMP 5 Trap Community Name For each Trap Community Name Click in the Trap Community Name textbox and specify a trap community name 6 Trap Host IP Address For each Trap Host IP Address Click in the Trap Host IP Address textbox and specify a trap host IP address 7 Cold Start Trap Click Cold Start Trap drop down menu f...

Page 62: ...k Up Trap drop down list to choose Enable or Disable to enable or disable link up trap 11 Authentication Failure Trap Click Authentication Failure Trap drop down menu from Authentication Failure Trap drop down list to choose Enable or Disable to enable or disable authentication failure trap 12 Topology Change Trap Click Topology Change Trap drop down menu from Topology Change Trap drop down list t...

Page 63: ...V1 V2C 1 Get Community Name Click in the Get Community Name textbox and specify a get community name 2 Set Community Name Click in the Set Community Name textbox and specify a set community name 3 Update Setting Click Update Setting button when you finished SNMP V1 V2c Setting ...

Page 64: ...lick Add User button The SNMP V3 Setting window appears 2 SNMP Version Click SNMP Version drop down menu from SNMP Version drop down list to choose SNMPv3 No Auth SNMPv3 Auth MD5 SNMPv3 Auth SHA SNMPv3 Priv Auth MD5 or SNMPv3 Priv Auth SHA SNMPv3 No Auth Add a user using SNMP v3 without authentication ...

Page 65: ...rivacy Click in the Auth Password textbox and specify an authentication password Click in the Privacy PassPhrase textbox and specify a privacy pass phrase 3 User Name Click in the User Name textbox and specify a user name for user using SNMP v3 4 Access Mode Click Access Mode drop down menu from Access Mode drop down list to choose Read Only or Read Write Read Only Add a user using SNMP v3 with re...

Page 66: ... 11 802 1X RADIUS CONFIGURATION 1 Radius Status Click Radius Status drop down menu from Radius Status drop down list to choose Enable or Disable to globally enable or disable authentication 2 Update Setting Click Update Setting button when you finished Radius Status Setting ...

Page 67: ...een the Switch and radius server This key must match the encryption used on the radius daemon All leading spaces are ignored but spaces within and at the end of the key are used If spaces are used in the key do not enclose the key in quotaion marks unless the quotation marks themselves are part of the key 5 Timeout 1 1000 Click in the Timeout textbox and specify the time interval in seconds that t...

Page 68: ... Radius button The Select Radius Server IP window appears 2 Select Radius Server IP Click Select Radius Server IP drop down menu from Select Radius Server IP drop down list to choose the IP address of the remote radius server host to be deleted 3 Submit Click Submit button when you finished radius server deletion ...

Page 69: ... Force Unauthorized to force a port state Auto specifies to enable authentication on port Force Authorized specifies to force a port to always be in an authorized state Force Unauthorized specifies to force a port to always be in an unauthorized state 4 Periodic Reauthentication Click Periodic Reauthentication drop down menu from Periodic Reauthentication drop down list to choose Enable or Disable...

Page 70: ...RP VLAN Registration Protocol 2 Dynamic VLAN creation Click Dynamic VLAN creation drop down menu from Dynamic VLAN creation drop down list to choose Enable or Disable to enable or disable Dynamic VLAN creation GARP Generic Attribute Registration Protocol provides IEEE802 1Q compliant VLAN pruning and dynamic VLAN creation on IEEE802 1Q trunk ports 3 Update Setting Click Update Setting button when ...

Page 71: ...g Tree Protocol blocking state which prevents the STP bridge protocol data units BPDUs from being pruned from the other port Ports in the GVRP normal applicant state do not declare GVRP VLANs when in the STP blocking state 3 GVRP registration Click GVRP registration drop down menu from GVRP registration drop down list to choose Enable or Disable to enable or disable GVRP registration to the port C...

Page 72: ...0 The query interval field is used to set the time in seconds between transmitting IGMP queries Entries between 1 and 18000 seconds are allowed Default 125 2 Max response time Click in the max response time textbox and specify a new number from 1 124 This determines the maximum amount of time in seconds allowed before sending an IGMP response report The max response time field allows an entry betw...

Page 73: ...ecify 0 to 23 5 Minute Click in Month text box and specify 0 to 59 6 Second Click in Month text box and specify 0 to 59 7 Submit Click Submit button when you finished Adjust RTC Time NTP Setting 1 NTP Status Click NTP Status drop down menu from NTP Status drop down list to choose Enable or Disable to enable or disable NTP for the Switch 2 NTP Server IP Address or Domain name Click in the NTP Serve...

Page 74: ...ht Saving time zone using the following example EDT East Daylight Saving Time Zone CDT Central Daylight Saving Time Zone MDT Mountain Daylight Saving Time Zone PDT Pacific Daylight Saving Time Zone ADT Alaska Daylight Saving Time Zone 4 Weekday Click in the textboxes and specify the daylight saving period Month Click Month drop down menu from Month drop down list to choose from January to December...

Page 75: ...onsole by Commend Line 7 1 ADMINISTRATION CONSOLE Connect the DB9 straight cable to the RS 232 serial port of the device to the RS 232 serial port of the terminal or computer running the terminal emulation application Direct access to the administration console is achieved by directly connecting a terminal or a PC equipped with a terminal emulation program such as HyperTerminal to the switch conso...

Page 76: ...N DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 76 7 1 1 EXEC MODE VIEW MODE LOGON TO EXEC MODE VIEW MODE At the switch_a login prompt just type in root and press Enter to logon to Exec Mode or View Mode switch_a login root ...

Page 77: ...ds like clear debug disable enable exit help logout no quit show terminal The CLI contains a text based help facility Access this help by typing in the full or partial command string then typing a question mark The CLI displays the command keywords or parameters along with a short description At the switch_a prompt just press to list the above basic commands switch_a ...

Page 78: ... 10112303 OSD2600 OPERATOR MANUAL PAGE 78 At the switch_a prompt just type in the full or partial command string then typing a question mark to display the command keywords or parameters along with a short description switch_a show ...

Page 79: ... Mode has timed out due to an extended period of inactivity 60 seconds to indicate authentication attempt timed out And the switch_a login prompt will show on the screen LOGON BACK TO EXEC MODE VIEW MODE At the switch_a login prompt just type in root and press Enter to logon back to Exec Mode or View Mode switch_a login root ...

Page 80: ...ICAL SYSTEMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 80 EXIT FROM EXEC MODE VIEW MODE At the switch_a prompt just type in exit and press Enter to exit from Exec Mode or View Mode switch_a exit ...

Page 81: ...L PAGE 81 7 1 2 PRIVELEDGED EXEC MODE ENABLE MODE LOGON TO PRIVILEGED EXEC MODE ENABLE MODE At the switch_a prompt just type in enable and press Enter to logon to Privileged Exec Mode or Enable Mode And the switch_a prompt will show on the screen switch_a enable ...

Page 82: ...STEMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 82 COMMANDS Privileged Exec Mode or Enable Mode allows users to run commands as following At the switch_a prompt just press to list the commands switch_a ...

Page 83: ... 10112303 OSD2600 OPERATOR MANUAL PAGE 83 At the switch_a prompt just type in the full or partial command string then typing a question mark to display the command keywords or parameters along with a short description switch_a show ...

Page 84: ... Enable Mode has timed out due to an extended period of inactivity 60 seconds to indicate authentication attempt timed out And the switch_a login prompt will show on the screen LOGON BACK TO EXEC MODE VIEW MODE At the switch_a login prompt just type in root and press Enter to logon back to Exec Mode or View Mode switch_a login root ...

Page 85: ...ESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 85 EXIT FROM PRIVILEGED EXEC MODE OR ENABLE MODE At the switch_a prompt just type in exit and press Enter to exit from Privileged Exec Mode or Enable Mode switch_a exit ...

Page 86: ...E MODE CONFIGURE TERMINAL MODE LOGON TO CONFIGURE MODE CONFIGURE TERMINAL MODE At the switch_a prompt just type in configure terminal and press Enter to logon to Configure Mode or Configure Terminal Mode And the switch_a config prompt will show on the screen switch_a configure terminal ...

Page 87: ...DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 87 COMMANDS Configure Mode or Configure Terminal Mode serves as a gateway into the modes as following At the switch_a config prompt just press to list the commands switch_a config ...

Page 88: ...03 OSD2600 OPERATOR MANUAL PAGE 88 At the switch_a config prompt just type in the full or partial command string then typing a question mark to display the command keywords or parameters along with a short description switch_a config show ...

Page 89: ...e Terminal Mode has timed out due to an extended period of inactivity 60 seconds to indicate authentication attempt timed out And the switch_a login prompt will show on the screen LOGON BACK TO EXEC MODE VIEW MODE At the switch_a login prompt just type in root and press Enter to logon back to Exec Mode or View Mode switch_a login root ...

Page 90: ...10112303 OSD2600 OPERATOR MANUAL PAGE 90 EXIT FROM CONFIGURE MODE OR CONFIGURE TERMINAL MODE At the switch_a config prompt just type in exit and press Enter to exit from Configure Mode or Configure Terminal Mode switch_a config exit ...

Page 91: ...tax no hostname HOSTNAME HOSTNAME specifies the network name of the system 4 Example The following example sets the hostname to switch and shows the change in the prompt switch_a config hostname switch switch config Password 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use enable password co...

Page 92: ...8 255 0 0 0 16 255 255 0 0 24 255 255 255 0 4 Example The following example sets the new IP address 192 168 1 10 and new IP subnet mask 255 255 255 0 to switch switch_a config interface vlan1 1 switch_a config if ip address 192 168 1 10 24 switch_a config if Default Gateway 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the scr...

Page 93: ... sets the DNS server 192 168 1 100 to switch switch_a config ip dns 192 168 1 100 switch_a config SAVE CONFIGURATION Load config from TFTP server 1 Command Mode Privileged Exec mode Logon to Privileged Exec Mode Enable Mode The switch_a prompt will show on the screen switch_a 2 Usage Use install image command to load configuration file from tftp server to switch 3 Command Syntax install image IP A...

Page 94: ...xec mode Logon to Privileged Exec Mode Enable Mode The switch_a prompt will show on the screen switch_a 2 Usage Use copy running config startup config command to write configurations to the file to be used at startup This is the same as the write memory command 3 Command Syntax copy running config startup config 4 Example The following example specifies writing configurations to the file to be use...

Page 95: ...xample enables or disables auto save configuration to switch switch_a config service auto config enable switch_a config no service auto config enable switch_a config Auto Save Interval 5 65536 sec 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to set the interval when the conf...

Page 96: ...ch 3 Command Syntax install image IP ADDRESS WORD IP ADDRESS specifies the IP address of tftp server WORD specifies the file name to be upgraded to switch 4 Example The following example specifies upgrading firmware file name flash tgz from tftp server IP address 192 168 1 100 to switch switch_a install image 192 168 1 100 flash tgz switch_a Please follow the message on the screen during the firmw...

Page 97: ...OPTICAL SYSTEMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 97 At the switch_a prompt just type in reload and press Enter to reboot the switch after completing the upgrade process ...

Page 98: ...interface 4 Example The following example enables alarm trigger on interface fe1 to switch switch_a config alarm trigger if fe1 switch_a config Alarm trigger power 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to enable or disable alarm trigger of power source 3 Command Synta...

Page 99: ...llowing example specifies restarting switch switch_a reload switch_a login LOGOUT 1 Command Mode Exec mode or Privileged Exec mode Logon to Exec Mode View Mode or Privileged Exec Mode Enable Mode The switch_a or switch_a prompt will show on the screen switch_a switch_a 2 Usage Use logout command to exit from the Exec mode or Privileged Exec mode 3 Command Syntax logout 4 Example The following exam...

Page 100: ...xample The following example shows the use of the shutdown command to shut down the interface fe1 port 1 switch_a config interface fe1 switch_a config if shutdown switch_a config if Bandwidth 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 ...

Page 101: ...uplex MODE MODE specifies the duplex mode auto full half 4 Example The following example shows the use of duplex MODE full to the interface fe1 port 1 switch_a config interface fe1 switch_a config if duplex full switch_a config if Flow control 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt wi...

Page 102: ...interface fe1 RATE CONTROL 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use this command to specify the ingress egress rate to be used for each interface The bandwidth value is in bits Use the no parameter with...

Page 103: ...ON statistics is desired 4 Example The following example shows the use of show interface statistics to display RMON statistics of the interface fe1 port 1 switch_a show interface statistics fe1 PER PORT VLAN ACTIVITIES 1 Command Mode Exec mode or Privileged Exec mode Logon to Exec Mode View Mode or Privileged Exec Mode Enable Mode The switch_a or switch_a prompt will show on the screen switch_a sw...

Page 104: ...NGTIME 1000 to bridge GROUP 1 switch_a config bridge 1 ageing time 1000 switch_a config Threshold level 0 100 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use storm control level command to specify the rising t...

Page 105: ...st enable to the interface fe1 port 1 switch_a config interface fe1 switch_a config if storm control broadcast enable switch_a config if Multicast 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use storm control ...

Page 106: ...rm control dlf enable switch_a config if STATIC MAC ENTRY Static MAC Entry Forward 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to statically configure a bridge entry to forward matching frames 3 Command Syntax bridge GROUP address MAC forward IFNAME VLANID no bridge GROUP a...

Page 107: ... config PORT MIRRORING 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use this command to define a mirror source port and its direction Use the no parameter with this command to disable port mirroring by the dest...

Page 108: ...ode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use poe enable command to enable this port to discover Powered Device PD connected to this port Use the no poe enable to disable this function 3 Command Syntax no poe enable 4 Example The fol...

Page 109: ...1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use this command to specify the fixed power limit for this port to provide power to PD 3 Command Syntax poe fixed power limit LEVEL LEVEL 1 15 4 specifies the fixed power limit Watts for this port to provide power to PD 4 Example The following example sets new fixed power l...

Page 110: ... Use the no poe power classification enable to disable this function 3 Command Syntax no poe power down alarm enable 4 Example The following example shows the use of poe power down alarm enable to the interface fe1 port 1 switch_a config interface fe1 switch_a config if poe power down alarm enable switch_a config if PoE Scheduling PoE Schedule 1 Command Mode Interface mode Logon to Configure Mode ...

Page 111: ...he screen switch_a config interface fe1 switch_a config if 2 Usage Use this command to set PoE scheduling to this port 3 Command Syntax poe schedule time DAY HOUR DAY 0 6 specifies Sunday Saturday to Switch HOUR 0 23 specifies hours to Switch no poe schedule time DAY 4 Example The following example sets PoE scheduling to the interface fe1 port 1 switch_a config interface fe1 switch_a config if poe...

Page 112: ...mand to create a static aggregator or add a member port to an already existing static aggregator Use the no static channel group command to detach the port from the static aggregator 3 Command Syntax static channel group 1 3 no static channel group 1 3 Channel group number Maximum 4 ports in static channel group 1 and static channel group 2 Maximum 2 ports in static channel group 3 4 Example The f...

Page 113: ...e following example chooses the PROTOCOL rstp on bridge GROUP 1 switch_a config bridge 1 protocol rstp vlan bridge switch_a config Multiple Spanning Tree Protocol 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to enable the Multiple Spanning Tree protocol on a bridge Use the n...

Page 114: ...tree on bridge GROUP 1 switch_a config bridge 1 rapid spanning tree enable switch_a config no bridge 1 rapid spanning tree enable bridge forward switch_a config Spanning Tree Protocol 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to enable the Spanning Tree protocol on a brid...

Page 115: ...ample sets the priority PRIORITY 4096 of bridge GROUP 1 switch_a config bridge 1 priority 4096 switch_a config Hello Time sec 1 9 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to set the hello time the time in seconds after which if this bridge is the root bridge all the brid...

Page 116: ...x age MAXAGE 28 of bridge GROUP 1 switch_a config bridge 1 max age 28 switch_a config Forward Delay sec 4 30 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to set the time in seconds after which if this bridge is the root bridge each port changes states to learning and forward...

Page 117: ...1 port 1 of bridge GROUP 1 switch_a config interface fe1 switch_a config if bridge 1 priority 100 switch_a config if Admin Path Cost 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use this command to set the cost...

Page 118: ...nsition shared Disable rapid transition 4 Example The following example sets the link type LINKTYPE point to point of the interface fe1 port 1 switch_a config interface fe1 switch_a config if spanning tree link type point to point switch_a config if Autoedge 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a conf...

Page 119: ...ig if MSTP PROPERTIES Region Name 1 Command Mode MST Configuration mode Logon to Configure Mode Configure Terminal Mode Then logon to MST Configuration mode The switch_a config mst prompt will show on the screen switch_a config spanning tree mst configuration switch_a config mst 2 Usage Use this command to create an MST region and specify a name to it MST bridges of a region form different spannin...

Page 120: ...g spanning tree mst configuration switch_a config mst bridge 1 revision 25 switch_a config mst Max Hops 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to specify the maximum allowed hops for BPDU in an MST region This parameter is used by all the instances of the MST Specifyin...

Page 121: ...ple VLANs 10 and 20 to instance 1 of bridge GROUP 1 switch_a config bridge 1 protocol mstp switch_a config spanning tree mst configuration switch_a config mst bridge 1 instance 1 vlan 10 20 switch_a config mst Bridge Instance Priority 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this com...

Page 122: ...nal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use this command to set the port priority for a bridge group The Multiple Spanning Tree Protocol uses port priority as a tiebreaker to determine which port should forward frames for a particular instance on a LAN or which port should ...

Page 123: ...parameter with this command to restore the default cost value of the path A lower path cost indicates a greater likelihood of the specific interface becoming a root 3 Command Syntax bridge GROUP instance INSTANCE_ID path cost PATH_COST GROUP 1 1 Specify the bridge group ID INSTANCE_ID 1 15 Specify the instance ID PATH_COST 1 200000000 Specify the cost of path in the range of 1 200000000 4 Example ...

Page 124: ... FORWARD Puts all ports of the specified bridge into the forwarding state 4 Example The following example enables Ring state in bridge GROUP 1 switch_a config bridge 1 protocol ring switch_a config Set ring port 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to set Ring port 1...

Page 125: ...show on the screen switch_a config vlan database switch_a config vlan 2 Usage This command enables or disables the state of a particular VLAN on a bridge basis Specifying the disable state causes all forwarding over the specified VLAN ID on the specified bridge to cease Specifying the enable state allows forwarding of frames on the specified VLAN aware bridge 3 Command Syntax vlan VLANID bridge GR...

Page 126: ...e access switch_a config if Switchport mode hybrid 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use switchport mode hybrid command to set the switching characteristics of the Layer 2 interface as hybrid and cla...

Page 127: ...Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use this command to set the switching characteristics of the Layer 2 interface to hybrid Both tagged and untagged frames will be classified over hybrid interfaces Use the no parameter to turn off allowed ...

Page 128: ... parameters will add and remove VLAN IDs to from the port s member set Use the no parameter to remove all VLAN IDs configured on this port 3 Command Syntax switchport trunk allowed vlan all switchport trunk allowed vlan none switchport trunk allowed vlan add VLANID switchport trunk allowed vlan remove VLANID switchport trunk allowed vlan except VLANID no switchport trunk vlan all Allow all VLANs t...

Page 129: ...t will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use this command to set or remove the default VLAN for the interface 3 Command Syntax switchport portbase add remove vlan VLANID VLANID The ID of the VLAN will be added to or removed from the Layer 2 interface 4 Example The following example specifies to add the interface fe1 port 1 to VLANID 2 switch_a config inter...

Page 130: ...witch_a config mls qos enable switch_a config Trust 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use mls qos trust command to turn on QoS trust CoS or DSCP Use the no mls qos trust command to turn off QoS trust CoS or DSCP 3 Command Syntax no mls qos trust cos dscp cos Class of Service dscp ...

Page 131: ... queues 3 Command Syntax wrr queue bandwidth WRR_WTS WRR_WTS Weighted Round Robin WRR weights for the 4 queues 4 values separated by spaces Range is 1 55 4 Example The following example specifies the bandwidth ratios of the transmit queues on the switch switch_a config wrr queue bandwidth 1 2 4 8 switch_a config 802 1P PRIORITY 1 Command Mode Configure mode Logon to Configure Mode Configure Termin...

Page 132: ...ch_a config 2 Usage Use mls qos map dscp queue command to map the DSCP values to a queue 3 Command Syntax mls qos map dscp queue DSCP_VALUE to QUEUE_ID DSCP_VALUE DSCP values Up to 8 values separated by spaces Range is 0 63 QUEUE_ID Queue ID Range is 0 3 4 Example The following example shows mapping DSCP values 0 to 3 to queue 1 on the switch switch_a config mls qos map dscp queue 0 1 2 3 to 1 swi...

Page 133: ...nmp server enable switch_a config Description 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use snmp server description command to specify and no snmp server description command to remove description for SNMP 3 Command Syntax snmp server description DESCRIPTION no snmp server description DESC...

Page 134: ...p server contact command to specify and no snmp server contact command to remove contact for SNMP 3 Command Syntax snmp server contact CONTACT no snmp server contact CONTACT The contact for SNMP 4 Example The following example specifies contact contact for SNMP switch_a config snmp server contact contact switch_a config Trap Community Name 1 Command Mode Configure mode Logon to Configure Mode Conf...

Page 135: ...C D specifies the IP address 4 Example The following example specifies trap host 1 IP address 192 168 1 20 for SNMP switch_a config snmp server trap ipaddress 1 192 168 1 20 switch_a config Cold Start Trap 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use snmp server trap type enable coldStar...

Page 136: ...e linkDown command to enable link down trap for SNMP Use the no snmp server trap type enable linkDown command to disable link down trap for SNMP 3 Command Syntax no snmp server trap type enable linkDown 4 Example The following example enables link down trap for SNMP switch_a config snmp server trap type enable linkDown switch_a config Link Up Trap 1 Command Mode Configure mode Logon to Configure M...

Page 137: ..._a config snmp server trap type enable authenticationFailure switch_a config Topology Change Trap 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use snmp server trap type enable topologyChange command to enable topology change trap for SNMP Use the no snmp server trap type enable topologyChang...

Page 138: ...itch_a config 2 Usage Use snmp server community set command to specify and no snmp server community set command to remove set community name for SNMP 3 Command Syntax snmp server community set NAME no snmp server community set NAME The set community name for SNMP 4 Example The following example specifies set community name name for SNMP switch_a config snmp server community set name switch_a confi...

Page 139: ... user name ro read only access mode rw read write access mode md5 authentication method sha authentication method AUTH_PASSWORD authentication password 4 Example The following example adds a user myuser using snmp v3 with read write access mode and MD5 authentication mypassword switch_a config snmp server v3 user myuser rw auth md5 mypassword switch_a config SNMPv3 Priv Auth MD5 SNMPv3 Priv Auth S...

Page 140: ...word PRIV_PASS_PHRASE encryption pass phrase 4 Example The following example adds a user myuser using snmp v3 with read write access mode MD5 authentication mypassword and encryption pass phrase mypassphrase switch_a config snmp server v3 user myuser rw priv md5 mypassword des mypassphrase switch_a config ...

Page 141: ...Server IP Radius Server Port 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to specify the IP address of the remote radius server host and assign authentication and accounting destination port number 3 Command Syntax no radius server host IP ADDRESS auth port PORT IP ADDRESS A...

Page 142: ...lient switch_a config radius server host 192 168 1 100 key ipi switch_a config Timeout 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to specify the number of seconds a Switch waits for a reply to a radius request before retransmitting the request 3 Command Syntax radius serve...

Page 143: ... 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use dot1x reauthetication command to enable reauthentication on a port Use no dot1x reauthetication command to disable reauthentication on a port 3 Command Syntax no dot1x reauthentication 4 Example The following example specifies to enable reauthetication on the interface fe1 port 1 s...

Page 144: ...on Period 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode fe1 means port 1 The switch_a config if prompt will show on the screen switch_a config interface fe1 switch_a config if 2 Usage Use this command to set the interval between reauthorization attempts Use no dot1x timeout re authperiod command to delete the interval between reauthoriza...

Page 145: ... bridge GROUP GROUP Bridge group ID used for bridging 4 Example The following example globally enables GVRP to bridge GROUP 1 switch_a config set gvrp enable bridge 1 switch_a config Dynamic VLAN creation 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use set gvrp dynamic vlan creation enable ...

Page 146: ...ce fe1 port 1 switch_a config set port gvrp enable fe1 switch_a config Per port setting GVRP applicant 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to set the GVRP applicant state to normal or active 3 Command Syntax set gvrp applicant state active normal IFNAME active Activ...

Page 147: ...ample The following example sets GVRP registration to fixed registration mode on the interface fe1 port 1 switch_a config set gvrp registration fixed fe1 switch_a config IGMP Snooping IGMP mode Querier 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use ip igmp snooping querier command to enabl...

Page 148: ...ans vlan 1 The switch_a config if prompt will show on the screen switch_a config interface vlan1 1 switch_a config if 2 Usage Use ip igmp version command to set the current IGMP protocol version on an interface To return to the default version use the no ip igmp version command 3 Command Syntax ip igmp version VERSION no ip igmp version VERSION IGMP protocol version number 4 Example The following ...

Page 149: ...Interface mode vlan1 1 means vlan 1 The switch_a config if prompt will show on the screen switch_a config interface vlan1 1 switch_a config if 2 Usage Use ip igmp query interval command to configure the frequency of sending IGMP host query messages To return to the default frequency use the no ip igmp query interval command 3 Command Syntax ip igmp query interval INTERVAL no ip igmp query interval...

Page 150: ...r port 1 Command Mode Interface mode Logon to Configure Mode Configure Terminal Mode Then logon to Interface mode vlan1 1 means vlan 1 The switch_a config if prompt will show on the screen switch_a config interface vlan1 1 switch_a config if 2 Usage Use ip igmp snooping mrouter interface command to statically configure the specified VLAN constituent interface as a multicast router interface for IG...

Page 151: ...pression for IGMPv2 reports on vlan1 1 switch_a config interface vlan1 1 switch_a config if ip igmp version 2 switch_a config if ip igmp snooping report suppression switch_a config if NTP Adjust RTC Time 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on the screen switch_a config 2 Usage Use this command to specify system time to ...

Page 152: ...t will show on the screen switch_a config 2 Usage Use this command to specify the IP address or Domain name of NTP server 3 Command Syntax ntp server IP ADDRESS DOMAIN NAME IP ADDRESS A B C D specifies the IP address of NTP server DOMAIN NAME Specifies the Domain name of NTP server 4 Example The following example specifies the IP address 192 168 1 100 of NTP server switch_a config ntp server 192 1...

Page 153: ...rval 3 Command Syntax ntp polling interval MINUTE MINUTE 1 10080 The polling interval Enter a value in the range 1 to 10080 minutes 4 Example The following example specifies the polling interval 60 minutes switch_a config ntp polling interval 60 switch_a config Daylight Saving Mode 1 Command Mode Configure mode Logon to Configure Mode Configure Terminal Mode The switch_a config prompt will show on...

Page 154: ...Release notes Ver 1 94 1 Add New protocol or commands All Chain protocol Add Chain Pass through protocol All LLDP Add LLDP protocol All CLI Add CLI command web UI can be disabled All CLI Add CLI command detach CPU All User Account Add Multi user Admin Technician Operator All System log Add System log Local remote All VLAN Add Port priority All Web interface Add Clear button for RMON statistics to ...

Page 155: ...ensive and may be damaged by failure of any portion of their support circuitry Some components within the unit are Electrostatic ES sensitive and Electrostatic Discharge ESD precautions should be taken when performing maintenance upon the unit 9 2 EXTERNAL INSPECTION Visually check for the following Check that the correct power source is connected to the power socket Check that the Ethernet cables...

Page 156: ...tive for all repairs 10 2 1 WARRANTY REPAIRS Return shipments to OSD shall be at customer s expense and freight back to the customer will be at OSD expense 10 2 2 OUT OF WARRANTY REPAIRS OSD reserves the right to repair or replace any faulty goods Freight costs and insurance for both journeys are met by the user All equipment repaired by OSD will have a 3 Month Warranty from the date of dispatch 1...

Page 157: ...OPTICAL SYSTEMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 157 ...

Page 158: ...OPTICAL SYSTEMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 158 ...

Page 159: ...OPTICAL SYSTEMS DESIGN DOC ID 10112303 OSD2600 OPERATOR MANUAL PAGE 159 ...

Page 160: ...Vuko Pl Warriewood 2102 P O Box 891 Mona Vale N S W Australia 2103 Telephone 61 2 9913 8540 Facsimile 61 2 9913 8735 Email sales osd com au Web Site www osd com au OPTIC L SYSTEMS DESIGN PTY LTD A B N 83 003 020 504 Printed in Australia ...

Reviews: