SECTION 4: OSCOR AUTOMATIC OPERATION
REI
OSC-5000E
78
To de-activate the screen during automatic operation:
1. Enter the Automatic Mode Output Configuration Menu as described above
2. Press the F4 button (labeled DISPLAY MODE) to toggle the Screen Display Mode.
With the screen in the Blanked Mode and the Automatic Mode activated, the screen will
remain blank until the AUTO/MANUAL button is pressed to stop the Automatic Mode.
Correlate Options - Acoustic Correlator System (Automatic)
Options at this level allow the user to change the threat level threshold, correlation
method, acquire time, and analyze time. For an overview of the acoustic correlator
system refer to page 53 (Acoustic Correlator System (Manual)). The correlator operation
is configured for the Automatic Mode using the Automatic Mode Set Up Menu.
NOTE
: With the OSCOR in the Automatic Mode, each signal detected is stored in the
OSCOR memory.
To enter the Correlator Set Up Menu:
1. From the CONFIGURE AUTO Menu, press the F4 button (labeled START AUTO).
2. Press the F2 button (labeled CONFIG CORR).
FIGURE 55 AUTO MODE CORRELATE SET-UP MENU
IN THIS MENU, THE FOLLOWING BUTTONS PERFORM THE INDICATED FUNCTIONS
F1 - toggles the Correlate method between LD FRND, PASSIVE, VERIFY, and
ACTIVE. These methods are described in detail in the following sub-sections.
F2 - toggles the Correlate ACQUIRE time window between 3, 5, and 10 seconds.
F3 - toggles the ANALYZE time window between 10, 30, and 60 seconds.
F4 - toggles through the available threat alert thresholds (2,3,4,or 5).
NOTE
: The ACQUIRE function is only applicable to the PASSIVE and VERIFY methods of
correlation
.
NOTE
: The ANALYZE function time selection is only applicable to the PASSIVE and
VERIFY methods of correlation. When a threat signal is detected in the Automatic Mode
of operation and the threat level exceeds the specified level, the alarm system is
activated. This alarm system activates the output options specified in Outputs on page 76
Output Options. The sensitivity of the correlator and alert system are adjusted by setting
the threat level threshold. It is recommended that the threat level be set to 3 or 4.
To clear an alert message and the flashing LED alert indicator:
1. Press the TONE button.