Stratford
Fireplace Installation and Operation Manual
__________________________________________________________________________ 77
Note
: Only remove the knock-out that will be connected to the fresh air inlet.
The fresh air intake kit may be installed on three different places on the fireplace.
1-
On the right side of the appliance (most common).
2-
On the right side, at the back of the appliance.
3-
On the right side under the appliance.
(1)
Using a Philips screwdriver,
remove the four screws holding
the rectangular plate
(A)
on the
right of the fireplace jacket. If the
location 2 or 3 has been chosen,
use pliers to remove the knock-
out.
(2)
Secure the fresh air intake kit
adapter
(B)
on the fireplace
jacket using the 4 screws
provided with the kit.