The duct system must be installed respecting the following:
1.
It is recommended to
wear gloves to perform
this procedure. Remove
the plates closing up the
8" dia. holes on top of the
fireplace. Then, cut and
remove the insulation in
order to obtain two 8"
dia. openings. Then,
remove the plates closing
up the 8" dia. holes inside
the fireplace.
2.
Secure the 2 anchor
plates (C) with 8 screws
provided (B) on top of
the fireplace (4 for each
anchor plate). Insert the
telescoping section (A)
into each anchor plate
and secure it with 6 other
self-tapping screws
provided (B).