background image

FREESTANDING INSTALLATION 

HYBRID-35 FREESTANDING PELLET STOVE 

 
Width: 22 1/2”  
Height: 29” 
Depth: 24 1/2” 
Weight: 195 lbs. 
Flue size: 3” or 4” 
Hopper Capacity: Up to 35 lbs. 
(This can vary slightly depending on pellet size, length, and diameter) 
EPA status: exempt 
Burn rate: 1.3 lbs to 4.1 lbs per hour 
BTU range: 8,200 to 35000 
Electrical consumption:  3.5 Amps lighting cycle 
                                       2.5 Amps. continuous duty 
Control board fuses:  Main: 7.5A-250V fastblow 
                                   Igniter: 5A-250V fastblow 
Electrical requirement: 120VAC 15A 
Approved installations: mobile home, conventional 
 

PREPARATION 

 
Factory packaging must be removed, and some minor assembly work is 
required prior to installation: 
 

 

The door overlay must be installed on the door frame; 

 

The louver kit must be installed in front of the heat exchanger; 

 

The black knob must be attached to the heat exchanger rod; 

 

The pedestal kits must be assembled to the body (freestanding 
version); 

 

The faceplate kit must be assembled to the body (insert version); 

 

Filters may be inserted between the finger guards and the 
convection blowers (see “filters assembly” section). 

 
NOTE:  The detailed instructions required to assemble the pedestal kit or 
faceplate kit are supplied with the corresponding kit.  Normally, your dealer 
will perform these functions. 
 
To remove ashes, use the ash pan or a vacuum cleaner.  If you want to 
use the ash pan, you will have to remove the plate located at the right side 
of the burn pot.   
 

1- 

Remove the three screws 

2- 

Remove the plate 

3- 

Put the three screws back 

4- 

Use the ash dump cap provided with the stove 

 

SI

D

E

 W

A

L

L

6"

BACK WALL

2" *

3"

 

Figure 1 

Back wall installation 

 
 

2"

3"

3"

2"

ADJACENT WALL

AD

JA
CENT

 W
A

LL

 

Figure 2 

Corner installation 

 

Summary of Contents for HYBRID-35

Page 1: ...y damage bodily injury or even death Save these instructions Some surfaces become hot at higher feeding rates To prevent potential burns avoid contact with those areas This heating unit must serve as...

Page 2: ...wood only Do not burn coal of any type in this appliance It is designed for residential installation according to current national and local building codes as a freestanding or insert room heater It i...

Page 3: ...in summer time may cause the heat sensors on the stove to activate the blowers disconnect the stove when not used for extended periods Contact your local building officials to obtain a permit and info...

Page 4: ...2 INSTALLATION THROUGH SIDE OF MASONRY CHIMNEY 12 INSERT INSTALLATION 13 INSERT INTO EXISTING MASONRY FIREPLACE 13 CLEARANCES 14 DOOR OVERLAY INSTALLATION 14 OPERATION 15 PROPER FUEL 15 PRE START UP C...

Page 5: ...G CODE I 28 STOVE STOPS FEEDING PELLETS AND SHOWS WARNING CODE O 28 STOVE STOPS FEEDING PELLETS AND SHOWS WARNING CODE H 29 STOVE STOPS FEEDING PELLETS AND SHOWS WARNING CODE d 29 SMOKE SMELL COMING B...

Page 6: ...e installed in front of the heat exchanger The black knob must be attached to the heat exchanger rod The pedestal kits must be assembled to the body freestanding version The faceplate kit must be asse...

Page 7: ...ceramic tile or any tile must be laid on a continuous non combustible sheet to prevent the possibility of embers falling through to the combustible floor if cracks or separation should occur in the fi...

Page 8: ...use a listed pellet vent that meets the ULC S 609 M89 and ULC ORD C441 M90 Standards For the United States we recommend that you use a listed pellet vent that meets the UL 641 7 th edition Standard Th...

Page 9: ...sure that they are cleaned on a regular basis as per our recommended maintenance schedule This is particularly critical if you have animals in your house such as a dog or a cat Filters that are not c...

Page 10: ...ot of horizontal run see Appendix A At least 3 feet of vertical rise are needed in all cases A longer vertical rise will favour a better exhaust 6 To reduce the risk of smoke spillage never terminate...

Page 11: ...r square hole in roof always 3 larger all the way around pipe Install upper edge and sides of flashing under roofing materials nail to the roof along upper edge Do not nail lower edge Seal nail heads...

Page 12: ...ter of the hole where the pipe is to pierce the masonry chimney 2 It will be necessary to cut out the masonry around the location of the pipe center mark Cut a 4 inch diameter hole for 3 inch pipe and...

Page 13: ...A through the floor Option B through the back wall Option C through chimney top 5 Attach the DuraVent adapter a section of pipe and clean out tee making sure the clean out tee is centered in the chim...

Page 14: ...LLATION In order to complete the assembly of your OSBURN HYBRID 35 you need to install the door overlay Figure 37 Door overlay installation 1 Position the overlay on the door frame and fix it in place...

Page 15: ...CK Remove burn pot making sure it is clean and none of the air holes are plugged Clean the firebox and then reinstall burn pot Clean door glass if necessary a dry cloth or paper towel is usually suffi...

Page 16: ...s a signal indicating that the unit has ignited This may take anywhere between 10 and 15 minutes FUEL FEED SWITCH By activating this function the stove will feed for 1 minute and the display will blin...

Page 17: ...corative panel for the insert This control is used to adjust the air intake manually depending on the type of installation and different brands of pellets used It allows you to improve the efficiency...

Page 18: ...OTE If an overheating situation occurs the high temperature switch called the L 250 manual reset will automatically shut down the auger motor fuel feed system and a warning code will appear b If the c...

Page 19: ...wall thermostat or a hand held thermostatic remote control you can locate the receiver behind the stove s back panel on the right side just below the terminal block Most receivers are already equippe...

Page 20: ...mostat does not call for heat after 45 minutes the unit will remain at the lowest heat setting 1 but will not shut down this is the PILOT ON mode The stove will remain at the lowest heat level until t...

Page 21: ...your stove is not connected to a thermostat or a fresh air supply do not leave it at the maximum setting If the ambient air becomes to hot the stove may overheat and the thermal protection on the com...

Page 22: ...e firebox into the ash drawer through the opening at the bottom of the firebox or vacuum to remove ashes WARNING Make sure ashes are cool to the touch before using a vacuum See VACUUM USE f Periodical...

Page 23: ...ure that the open side of the baffle is located on the left c Chamber walls Periodically you must vacuum the ashes that may have accumulated on the main walls of the combustion chamber START BY REMOVI...

Page 24: ...CONNECTOR Figure 50 Exhaust blower cleaning CHIMNEY CLEANING a Creosote Formation When wood is burned slowly it produces tar and other organic vapours which combine with expelled moisture to form creo...

Page 25: ...t Blower Vacuum Pressure Switch Tap Brush Venting System Inspect Sweep Gaskets Inspect Hopper Empty Vacuum Gasket around door and door glass should be inspected and repaired or replaced when necessary...

Page 26: ...xhaust pipe are blocked with ash or foreign material Follow all cleaning procedures in the maintenance section of the owner s manual 3 Vent pipe is incorrectly installed Check to make sure vent pipe i...

Page 27: ...shaft from the auger housing Start by emptying the hopper Take off the rear panel of the stove s body Then remove the auger motor by removing the screws holding the motor to the auger shaft Once the m...

Page 28: ...n occurs call your dealer or technician 5 The control board is not sending power to the igniter Check the voltage going to the igniter during ignition It should be a full current If the voltage is low...

Page 29: ...aintenance procedures Press simultaneously for 2 seconds and icons After 3 attempts reset is no longer possible Call SBI technical support STOVE STOPS FEEDING PELLETS AND SHOWS WARNING CODE d Possible...

Page 30: ...the vent pipe has been installed according to the instructions in the owner s manual 3 The air damper is too far closed for a higher setting Slide the air supply to a higher setting and try to burn th...

Page 31: ...erted polarity in power outlet Will not keep the stove from operating Power outage Igniter fuse blew up SMOKE SMELL OR SOOT BUILD UP Because it is a wood burning device your HYBRID 35 may emit a faint...

Page 32: ...BLOWER CONVECTION BLOWER EXHAUST AUGER MOTOR Figure 53 Components rear GH TEMPERATURE WITCH L 250 ANUAL RESET HIGH TEMPERATURE SWITCH L 250 AUTOMATIC HIGH TEMPERATURE SWITCH F 160 AIR SUPPLY CONTROL I...

Page 33: ...urn pot gasket 2 requires 21045 Control Board Touch screen 44022 PC Board 44102 Combustion Exhaust Blower Assembly SE44101 Convection Blower 44100 Door Gasket AC06100 Hot Rod Igniter 44030 Thermistor...

Page 34: ...tal vent coming out at the back of the stove on a total distance of 4 feet followed by a Tee and a 6 foot vertical rise it would be acceptable The installation would end be within the allowable config...

Page 35: ...uivalent vent lenght calculation table DRAW YOUR INSTALLATION 1 SQUARE 1 F00T PART DAILY 10 bags 25 bags E xchanger Baffle Left interior channel Hopper Evacuation blower Blower blades Pressure system...

Page 36: ...ased on predetermined rate schedule and must not exceed the wholesale price of the replacement part All labour and freight costs covered by this warranty are limited according to the table below The m...