7
CLEARANCES
The HYBRID-35 has been tested and listed for installation in regular and
mobile homes.(refer figure 1 & 2)
FLOOR PROTECTION: minimum 6” in the front and 6” on each side. The
stove must be placed on a continuous (grouted joints) non-combustible
material such as ceramic tile, cement board, brick, 3/8” millboard or
equivalent, or other approved or listed material suited for floor protection.
NOTE: ceramic tile, or any tile, must be laid on a continuous non
combustible sheet to prevent the possibility of embers falling through to the
combustible floor if cracks or separation should occur in the finished
surface, this also applies to floor protection for Built-in raised hearths.
Check local codes for approved alternatives.
Clearances are measured from the sides, back and face (door opening) or
stove body (refer to fig. 3).
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN THE
INSTALLATION OF THIS UNIT.
INSTALL VENT WITH CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
6"
6"
6"
Figure 3
Floor protection