SAFETY PRECAUTIONS 

 

 

 

Do not operate your stove if you 

smell smoke coming from it.  Turn it off, 
monitor it, and call your dealer. 

DO NOT 

UNPLUG IT

 

 

 

Keep foreign objects out of the hopper. 

 

 

Never use gasoline, gasoline-type 

lantern fuel, kerosene, charcoal lighter fluid, or 
similar liquids to start or “freshen up” a fire in 
this stove. Keep all such liquids well away from 
the stove while in use. 

 

 

Do not throw this manual away. This 

manual has important operating and maintenance 
instructions that you will need at a later time. 
Always follow the instructions in this manual. 

 

 

Never block free airflow through the 

open vents of the stove. 

 

Do not place clothing or other 

flammable items on or near the stove. 

 

 

Never try to repair or replace any 

part of the stove unless instructions are given 
in this manual. All other work should be done 
by a trained technician. 

 

 

The viewing door must be closed and 

latched during operation. 

 

 

The stove will not operate during a 

power outage. If an outage does occur, check 
the stove for smoke spillage and open a 
window if any smoke spills into the room. 

 

 

Do not operate the stove if the flame 

becomes dark and sooty or if the burnpot overfills 
with pellets. Turn the stove off, inspect it, and call 
your dealer. 

 

 

Disconnect the power cord before 

performing any maintenance or repairs on the 
stove. 

NOTE:

 Turning the stove “off” does not 

disconnect all power from the stove.

 

 

Do not touch the hot surfaces of the 

heater. Educate all children of the danger of a 
high temperature stove. Young children should be 
supervised when they are in the same room as 
the stove. 

 

 

Do not unplug the stove if you 

suspect a malfunction. Turn the stove off, 
inspect it, and call your dealer. 

 

 

High ambient temperature in summer 

time may cause the heat sensors on the stove to 
activate the blowers, disconnect the stove when 
not used for extended periods.

 

 

Contact your local building officials to 

obtain a permit and information on any 
installation restrictions or inspection 
requirements in your area. Notify your 
insurance company. 

 

 

The exhaust system 

must

 be 

completely airtight and properly installed. All vent 
connector joints must be sealed and fastened in 
accordance with the pellet pipe manufacturer's 
instructions to ensure consistent performance and 
avoid smoke and ash spillage. 

 

 

This unit must be properly installed to 

prevent the possibility of a house fire. The 
instructions must be strictly adhered to. Do not 
use makeshift methods or compromise in the 
installation. 

 

 

Your stove requires maintenance and 

cleaning. Failure to maintain your stove may lead 
to smoke spillage in your home. 

 

 

Allow the stove to cool before 

carrying out any maintenance or cleaning. 
Ashes must be disposed or stored in a metal 
container with a tight lid and placed on a non 
combustible surface well away from the home 
structure. 

 

 

This stove is designed and approved for 

pelletized wood fuel only. Any other type of fuel 
burned in this heater will void the warranty. 

 

 

This stove must be connected to a 

standard 120 V., 60 Hz grounded electrical 
outlet. Do not use an adapter plug or sever the 
grounding plug. Do not route the electrical cord 
underneath, in front of, or over the stove. 

 

 

When installed in a mobile home, the 

stove must be bolted to the floor, have outside air, 
and 

NOT BE INSTALLED IN A BEDROOM

 (Per 

H.U.D. requirements). Check with local building 
officials. 

 

 

The exhaust system should be 

checked,  at least twice a year for any build up 
of soot or creosote. 

 

 

Stove Builder International Inc. 

grants no warranty, implied or stated, for the 
installation or maintenance of your stove, and 
assumes no responsibility of any 
consequential damage(s).

 

 

 

 

 

Summary of Contents for HYBRID-35

Page 1: ...y damage bodily injury or even death Save these instructions Some surfaces become hot at higher feeding rates To prevent potential burns avoid contact with those areas This heating unit must serve as...

Page 2: ...wood only Do not burn coal of any type in this appliance It is designed for residential installation according to current national and local building codes as a freestanding or insert room heater It i...

Page 3: ...in summer time may cause the heat sensors on the stove to activate the blowers disconnect the stove when not used for extended periods Contact your local building officials to obtain a permit and info...

Page 4: ...2 INSTALLATION THROUGH SIDE OF MASONRY CHIMNEY 12 INSERT INSTALLATION 13 INSERT INTO EXISTING MASONRY FIREPLACE 13 CLEARANCES 14 DOOR OVERLAY INSTALLATION 14 OPERATION 15 PROPER FUEL 15 PRE START UP C...

Page 5: ...G CODE I 28 STOVE STOPS FEEDING PELLETS AND SHOWS WARNING CODE O 28 STOVE STOPS FEEDING PELLETS AND SHOWS WARNING CODE H 29 STOVE STOPS FEEDING PELLETS AND SHOWS WARNING CODE d 29 SMOKE SMELL COMING B...

Page 6: ...e installed in front of the heat exchanger The black knob must be attached to the heat exchanger rod The pedestal kits must be assembled to the body freestanding version The faceplate kit must be asse...

Page 7: ...ceramic tile or any tile must be laid on a continuous non combustible sheet to prevent the possibility of embers falling through to the combustible floor if cracks or separation should occur in the fi...

Page 8: ...use a listed pellet vent that meets the ULC S 609 M89 and ULC ORD C441 M90 Standards For the United States we recommend that you use a listed pellet vent that meets the UL 641 7 th edition Standard Th...

Page 9: ...sure that they are cleaned on a regular basis as per our recommended maintenance schedule This is particularly critical if you have animals in your house such as a dog or a cat Filters that are not c...

Page 10: ...ot of horizontal run see Appendix A At least 3 feet of vertical rise are needed in all cases A longer vertical rise will favour a better exhaust 6 To reduce the risk of smoke spillage never terminate...

Page 11: ...r square hole in roof always 3 larger all the way around pipe Install upper edge and sides of flashing under roofing materials nail to the roof along upper edge Do not nail lower edge Seal nail heads...

Page 12: ...ter of the hole where the pipe is to pierce the masonry chimney 2 It will be necessary to cut out the masonry around the location of the pipe center mark Cut a 4 inch diameter hole for 3 inch pipe and...

Page 13: ...A through the floor Option B through the back wall Option C through chimney top 5 Attach the DuraVent adapter a section of pipe and clean out tee making sure the clean out tee is centered in the chim...

Page 14: ...LLATION In order to complete the assembly of your OSBURN HYBRID 35 you need to install the door overlay Figure 37 Door overlay installation 1 Position the overlay on the door frame and fix it in place...

Page 15: ...CK Remove burn pot making sure it is clean and none of the air holes are plugged Clean the firebox and then reinstall burn pot Clean door glass if necessary a dry cloth or paper towel is usually suffi...

Page 16: ...s a signal indicating that the unit has ignited This may take anywhere between 10 and 15 minutes FUEL FEED SWITCH By activating this function the stove will feed for 1 minute and the display will blin...

Page 17: ...corative panel for the insert This control is used to adjust the air intake manually depending on the type of installation and different brands of pellets used It allows you to improve the efficiency...

Page 18: ...OTE If an overheating situation occurs the high temperature switch called the L 250 manual reset will automatically shut down the auger motor fuel feed system and a warning code will appear b If the c...

Page 19: ...wall thermostat or a hand held thermostatic remote control you can locate the receiver behind the stove s back panel on the right side just below the terminal block Most receivers are already equippe...

Page 20: ...mostat does not call for heat after 45 minutes the unit will remain at the lowest heat setting 1 but will not shut down this is the PILOT ON mode The stove will remain at the lowest heat level until t...

Page 21: ...your stove is not connected to a thermostat or a fresh air supply do not leave it at the maximum setting If the ambient air becomes to hot the stove may overheat and the thermal protection on the com...

Page 22: ...e firebox into the ash drawer through the opening at the bottom of the firebox or vacuum to remove ashes WARNING Make sure ashes are cool to the touch before using a vacuum See VACUUM USE f Periodical...

Page 23: ...ure that the open side of the baffle is located on the left c Chamber walls Periodically you must vacuum the ashes that may have accumulated on the main walls of the combustion chamber START BY REMOVI...

Page 24: ...CONNECTOR Figure 50 Exhaust blower cleaning CHIMNEY CLEANING a Creosote Formation When wood is burned slowly it produces tar and other organic vapours which combine with expelled moisture to form creo...

Page 25: ...t Blower Vacuum Pressure Switch Tap Brush Venting System Inspect Sweep Gaskets Inspect Hopper Empty Vacuum Gasket around door and door glass should be inspected and repaired or replaced when necessary...

Page 26: ...xhaust pipe are blocked with ash or foreign material Follow all cleaning procedures in the maintenance section of the owner s manual 3 Vent pipe is incorrectly installed Check to make sure vent pipe i...

Page 27: ...shaft from the auger housing Start by emptying the hopper Take off the rear panel of the stove s body Then remove the auger motor by removing the screws holding the motor to the auger shaft Once the m...

Page 28: ...n occurs call your dealer or technician 5 The control board is not sending power to the igniter Check the voltage going to the igniter during ignition It should be a full current If the voltage is low...

Page 29: ...aintenance procedures Press simultaneously for 2 seconds and icons After 3 attempts reset is no longer possible Call SBI technical support STOVE STOPS FEEDING PELLETS AND SHOWS WARNING CODE d Possible...

Page 30: ...the vent pipe has been installed according to the instructions in the owner s manual 3 The air damper is too far closed for a higher setting Slide the air supply to a higher setting and try to burn th...

Page 31: ...erted polarity in power outlet Will not keep the stove from operating Power outage Igniter fuse blew up SMOKE SMELL OR SOOT BUILD UP Because it is a wood burning device your HYBRID 35 may emit a faint...

Page 32: ...BLOWER CONVECTION BLOWER EXHAUST AUGER MOTOR Figure 53 Components rear GH TEMPERATURE WITCH L 250 ANUAL RESET HIGH TEMPERATURE SWITCH L 250 AUTOMATIC HIGH TEMPERATURE SWITCH F 160 AIR SUPPLY CONTROL I...

Page 33: ...urn pot gasket 2 requires 21045 Control Board Touch screen 44022 PC Board 44102 Combustion Exhaust Blower Assembly SE44101 Convection Blower 44100 Door Gasket AC06100 Hot Rod Igniter 44030 Thermistor...

Page 34: ...tal vent coming out at the back of the stove on a total distance of 4 feet followed by a Tee and a 6 foot vertical rise it would be acceptable The installation would end be within the allowable config...

Page 35: ...uivalent vent lenght calculation table DRAW YOUR INSTALLATION 1 SQUARE 1 F00T PART DAILY 10 bags 25 bags E xchanger Baffle Left interior channel Hopper Evacuation blower Blower blades Pressure system...

Page 36: ...ased on predetermined rate schedule and must not exceed the wholesale price of the replacement part All labour and freight costs covered by this warranty are limited according to the table below The m...

Reviews: