-74-
-75-
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Write(Set) –
0
x
02
(
2
)
* Control Value: The ranges of each
1
Byte of IP Address, Subnet Mask, Default Gateway, DNS Primary, or DNS Secondary are from
0
(
0
x
00
) to
255
(
0
xFF)
-
Receive From LCD
STX
CMD
Ex CMD
Length
Data
Check Sum
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
x
74
0
x
01
0
x
17
Variable
Variable
Variable
Variable
Variable
0
x
03
IP Address
(
4
Byte)
Subnet Mask
(
4
Byte)
Default Gateway
(
4
Byte)
DNS Primary
(
4
Byte)
DNS Secondary
(
4
Byte)
Value
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Write(Set)Response –
0
x
02
(
2
)
*Control : The ranges of each
1
Byte of IP Address, Subnet Mask, Default Gateway, DNS Primary, or DNS Secondary are from
0
(
0
x
00
) to
255
(
0
xFF)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
6
.
6
. Get LCD Network IP
-
This is the command for checking the configuration for LCD Network IP such as DHCP settings, IP Address, Subnet Mask, Default Gateway, DNS
Primary, and DNS Secondary.
-
CMD :
0
x
75
-
Send To LCD
STX
CMD
Ex CMD
Length
Data
ETX
Group ID
Multi ID
Mode
Value
0
x
02
0
x
75
0
x
01
0
x
03
Variable
Variable
Variable
0
x
03
*Group/Multi ID Range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get) –
0
x
00
(
0
)
-
Receive From LCD
STX
CMD
Ex CMD
Length
Data
Check Sum
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
x
75
0
x
01
0
x
18
Variable
Variable
Variable
Variable
Variable
0
x
03
DHCP ON,OFF
(
1
Byte)
IP Address
(
4
Byte)
Subnet Mask
(
4
Byte)
Default Gateway
(
4
Byte)
DNS Primary
(
4
Byte)
DNS Secondary
(
4
Byte)
Value
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
Va
ria
ble
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get) –
0
x
00
(
0
)
*Control: If DHCP configuration is deselected, it is
0
(
0
x
00
). If it is selected, it is
1
(
0
x
01
). The length of IP Address, Subnet Mask, Default Gateway,
DNS Primary, and DNS Secondary is
4
Bytes, respectively.
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
6
.
7
. Get MAC Address
-
This is the command for checking MAC Address.
-
CMD :
0
x
76
-
Send To LCD
STX
CMD
Ex CMD
Length
Data
ETX
Group ID
Multi ID
Mode
Value
0
x
02
0
x
76
0
x
01
0
x
03
Variable
Variable
Variable
0
x
03
*Group/Multi ID Range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get) –
0
x
00
(
0
)
-
Receive From LCD
STX
CMD
Ex CMD
Length
Data
Check Sum
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
x
76
0
x
01
0
x
09
Variable
Variable
Variable
Variable
Variable
0
x
03
Mac Address
(
1
Byte)
Mac Address
(
1
Byte)
Mac Address
(
1
Byte)
Mac Address
(
1
Byte)
Mac Address
(
1
Byte)
Mac Address
(
1
Byte)
Value
Variable
Variable
Variable
Variable
Variable
Variable
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get) –
0
x
00
(
0
)
*Control Value: The range of each value is from
0
(
0
x
00
) to
255
(
0
xFF).
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
6
.
8
. Baud Rate
-
This is the command for configuring the Baud Rate for LCD communication.
-
It is available only during Power On (Operative) status.
-
CMD :
0
x
78
-
Send To LCD
STX
CMD
Ex CMD
Length
Data
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
x
78
0
x
01
0
x
04
Variable
Variable
Variable
Variable
0
x
03
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Write(Set) –
0
x
02
(
2
)
*Control :
9600
–
1
(
0
x
01
),
14400
–
2
(
0
x
02
),
19200
–
3
(
0
x
03
),
38400
–
4
(
0
x
04
),
57600
–
5
(
0
x
05
),
115200
-
6
(
0
x
06
)
-
Receive From LCD
STX
CMD
Ex CMD
Length
Data
Check Sum
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
x
78
0
x
01
0
x
04
Variable
Variable
Variable
Variable
Variable
0
x
03
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Write(Set)Response –
0
x
02
(
2
)
*Control :
9600
–
1
(
0
x
01
),
14400
–
2
(
0
x
02
),
19200
–
3
(
0
x
03
),
38400
–
4
(
0
x
04
),
57600
–
5
(
0
x
05
),
115200
-
6
(
0
x
06
)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
6
.
9
. Get Baud Rate Data
-
This is the command for checking the configuration of the Baud Rate for LCD communication.
-
It is available only during Power On (Operative) status.
-
CMD :
0
x
79
-
Send To LCD
STX
CMD
Ex CMD
Length
Data
ETX
Group ID
Multi ID
Mode
Value
0
x
02
0
x
79
0
x
01
0
x
03
Variable
Variable
Variable
0
x
03
Summary of Contents for OLS-8410NL
Page 45: ...86 Memo...