-70-
-71-
*Control Value :
0
x
00
(
0
)~
0
x
64
(
100
)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
5
.
2
. V Position
-
This is the command to control the vertical position of the image within the Display area of the LCD.
-
CMD :
0
x
37
-
Send To LCD
STX
CMD
Ex CMD
Length
Data
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
x
37
0
x
01
0
x
04
Variable
Variable
Variable
Variable
0
x
03
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get) –
0
x
00
(
0
), Write(Set) –
0
x
02
(
2
)
*Control Value :
0
x
00
(
0
)~
0
x
64
(
100
)
-
Receive From LCD
STX
CMD
Ex CMD
Length
Data
Check Sum
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
x
37
0
x
01
0
x
04
Variable
Variable
Variable
Variable
Variable
0
x
03
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get)Response –
0
x
00
(
0
), Write(Set)Response –
0
x
02
(
2
)
*Control Value :
0
x
00
(
0
)~
0
x
64
(
100
)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
5
.
3
. Aspect Ratio
-
Aspect ratio can be selected or changed to
16
:
9
or
4
:
3
.
-
CMD :
0
xB
6
-
Send To LCD
STX
CMD
Ex CMD
Length
Data
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
xB
6
0
x
01
0
x
04
Variable
Variable
Variable
Variable
0
x
03
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get) –
0
x
00
(
0
) , Write(Set) –
0
x
02
(
2
)
*Control Value:
0
x
01
(
1
) for
16
:
9
,
0
x
02
(
2
) for
4
:
3
.
-
Receive From LCD
STX
CMD
Ex CMD
Length
Data
Check Sum
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
xB
6
0
x
01
0
x
04
Variable
Variable
Variable
Variable
Variable
0
x
03
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get)Response –
0
x
00
(
0
), Write(Set)Response –
0
x
02
(
2
)
*Control Value:
0
x
01
(
1
) for
16
:
9
,
0
x
02
(
2
) for
4
:
3
.
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
5
.
4
. Video Mute
-
It is the command for selecting Video Mute.
-
User can select blank screen.
-
CMD :
0
xB
7
-
Send To LCD
STX
CMD
Ex CMD
Length
Data
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
xB
7
0
x
01
0
x
04
Variable
Variable
Variable
Variable
0
x
03
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get) –
0
x
00
(
0
) , Write(Set) –
0
x
02
(
2
)
*Control : Blank –
0
x
00
(
0
) , Unblank –
0
x
01
(
1
)
-
Receive From LCD
STX
CMD
Ex CMD
Length
Data
Check Sum
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
xB
7
0
x
01
0
x
04
Variable
Variable
Variable
Variable
Variable
0
x
03
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get)Response –
0
x
00
(
0
), Write(Set)Response –
0
x
02
(
2
)
*Control : Blank –
0
x
00
(
0
) , Unblank –
0
x
01
(
1
)
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
5
.
5
. Get Screen Control Data
-
Get the adjusted data for Horizontal and Vertical Position, Aspect Ratio, Video Mute(Blank, Unblank), and Panel Key Lock(Key Lock , Unlock)
-
CMD :
0
x
93
-
Send To LCD
STX
CMD
Ex CMD
Length
Data
ETX
Group ID
Multi ID
Mode
Value
0
x
02
0
x
93
0
x
01
0
x
03
Variable
Variable
Variable
0
x
03
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get) –
0
x
00
(
0
)
-
Receive From LCD
STX
CMD
Ex CMD
Length
Data
Check Sum
ETX
Group ID
Multi ID
Mode
Control
Value
0
x
02
0
x
93
0
x
01
0
x
08
Variable
Variable
Variable
Variable
Variable
0
x
03
H Position
(
1
Byte)
V Position
(
1
Byte)
Aspect Ratio
(
1
Byte)
Video Mute
(
1
Byte)
Panel Key Lock
(
1
Byte)
Value
Variable
Variable
Variable
Variable
Variable
*Group ID/Multi ID range(Program) : Group ID :
0
x
01
/ Multi ID :
0
x
01
Fixed
*Mode : Read(Get)Response –
0
x
00
(
0
)
*Control: each data is
1
Byte and the rages of H Position is
0
(
0
x
00
)~
100
(
0
x
64
), V Position is
0
(
0
x
00
)~
100
(
0
x
64
).
For the Aspect Ratio,
1
(
0
x
01
) is
16
:
9
and
2
(
0
x
02
) is
4
:
3
.
For the Video Mute,
0
(
0
x
00
) is Blank and
1
(
0
x
01
) is Unblank.
For the Panel Key Lock,
0
(
0
x
00
) is Unlock,
1
(
0
x
01
) is Key Lock
*Check Sum: Execute "Not" operation after adding all the values in "STX~Data" area.
6
. SETUP A Command
6
.
1
. Auto Power
-
This is the command for selecting or deselecting Automatic Power On.
-
CMD :
0
x
64
Summary of Contents for OLS-8410NL