background image

18 

 

 

 

2200/ 3000VA 230V

 

 
 
 
 
 
 
 
 
 
 

Item Description 

Data Line Connectors 

Voltage Configuration Switch 

3 USB 

Port 

 

RS232 (DB-9) Port 

5-1 

10A Output Circuit Breaker for 6-1 

5-2 

10A Output Circuit Breaker for 6-2 

6-1 

IEC-320-C13 Output Receptacles   

6-2 

IEC-320-C13 Output Receptacles   

6-3 

IEC-320-C19 Output Receptacles 

7 Cooling 

Vents 

15A Input Circuit Breaker(2200 model only) 
20A Input Circuit Breaker(3000 model only) 

IEC-320-C20 Input Socket 

10 REPO 
11 Intellislot 

Port 

 

19 

 

 

INSTALLATION 

 

4.1 

  Connect Utility and Load 

 
 
First, connect the UPS with utility power, then plug the loads into the 

outlets on the rear of the UPS.    To use the UPS as a master “On/Off” 
switch, make sure that all of the loads are switched “on”. 

These UPS outlets provide battery backup and surge protection to the 

equipment when utility voltage is out of specification. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Caution--- 

Do not connect a laser printer to the UPS outlets!

 

Summary of Contents for Network Pro 1000

Page 1: ...D Display Panel 13 3 10 UPS Rear Panel 14 4 INSTALLATION 19 4 1 Connect Utility and Load 19 4 2 Connect Network Surge protection 20 4 3 Connect Computer Interface Port 20 4 4 REPO Switch 21 5 OPERATIO...

Page 2: ...ay USB RS232 interface conveniently offers a USB or RS232 port for connecting to a computer or other hardware 3 2 IMPORTANT SAFETY INSTRUCTION 2 1 An Important Notice 1 The UPS has its own internal en...

Page 3: ...overcurrent protection in accordance with the National Electric Code ANSI NFPA 70 5 24 CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE...

Page 4: ...eration of UPS The UPS should be stored and operated in a well ventilated and climate controlled low humidity environment 7 3 3 Unpacking 1 Take the UPS out of the packing foam 2 Remove the packing ma...

Page 5: ...e ensure the installation site environmental conditions meet the UPS specifications to avoid overheating and excessive moisture and to prolong battery life 4 Do not place the UPS in a dusty or corrosi...

Page 6: ...10 3 7 Rack Mount Setup Step1 Step2 11 Step3 Step4 Step5...

Page 7: ...n Switch 4 Off Switch 5 Battery Replacement 6 Battery Backup LED 7 Battery Low 8 Bypass 9 Utility Low UPS Boost 10 Utility High UPS Buck 11 UPS Output Indicator 12 Polarity Error or Ground Fault 13 Ov...

Page 8: ...reaker 1500 model only 9 NEMA 5 15P Input Power Core 10 REPO 11 Intellislot Port 15 2200VA 120V 1920VA 1920W for UL Item Description 1 Data Line Connectors 2 Voltage Configuration Switch 3 USB Port 4...

Page 9: ...R Output Receptacles 7 Cooling Vents 8 30A Input Circuit Breaker 9 NEMA L5 30P Input Power Core 10 REPO 11 Intellislot Port 17 750 1000 1500VA 230V Item Description 1 Data Line Connectors 2 Voltage Co...

Page 10: ...Breaker 2200 model only 20A Input Circuit Breaker 3000 model only 9 IEC 320 C20 Input Socket 10 REPO 11 Intellislot Port 19 4 INSTALLATION 4 1 Connect Utility and Load First connect the UPS with utili...

Page 11: ...e port on the rear of the UPS and the computer interface port See software installation guide in the CD ROM Optional for installation purpose 21 4 4 REPO Switch The UPS is equipped with an Emergency P...

Page 12: ...the audible alarm beep sounding every 2 seconds in case of blackout or over under voltage Once normal utility power is restored the UPS will run under Utility mode and the audible alarm will be silenc...

Page 13: ...nt information Caution The UPS will not provide power to the outlets if the if the start up operation is not completed properly Important Notice Plug the UPS onto the wall receptacle to charge the UPS...

Page 14: ...26 6 2 How to Replace Battery STEP 1 STEP 2 27 STEP 3 STEP 4 750 1000 1500VA...

Page 15: ...DB 9 9 pin female connector on the rear to allow UPS status communications with a computer running UPS software The connection provides serial communication On Battery and Low Battery signals Table 4...

Page 16: ...act is 40Vdc 25mA 8 1 4 Installation Position Optional Slot 8 1 5 Flexible signal output for N C Normal Close or N O Normal Open contact by shorting pin1 2 or pin2 3 form JP1 5 8 1 6 The shutdown func...

Page 17: ...10 120 Shutdown after 10 minutes Normal Mode 120 Shutdown UPS immediately 100 119 Continuous Overload Alarm till end of battery discharged 120 130 Shutdown after 10 seconds Battery Mode 130 Shutdown U...

Page 18: ...problem Date of failure or problem Customer contact information and return address If repair is necessary you will be given a Returned Material Authorization RMA number The RMA number must appear on...

Reviews: