TGPS-9164GT-M12 Series User
Manual
ORing Industrial Networking Corp
13
3.2.1
Grounding
Grounding and wire routing help limit the effects of noise due to electromagnetic interference
(EMI). Run the ground connection on the power connector to the grounding surface prior to
connecting devices.
3.2.2
Fault Relay
The switch uses the M12 A-coded 5-pin male connector on the front panel for relay output. Use
a power cord with an M12 A-coded 5-pin female connector to connect the relay contacts from
the switch. The relay contacts will detect user-configured events and form an open circuit when
an event is triggered.
.
3.2.3
Redundant Power Inputs
The switch provides two sets of power supply on a M23 5-pin connector to enable dual power
inputs.
Step 1
: Insert a power cable to the power connector on the device.
Step 2
: Rotate the outer ring of the cable connector until a snug
fit is achieved. Make sure
the connection is tight.
3.3 Connection
3.3.1
Cables
10/100/1000BASE-T(X) Pin Assignments
The device provides Ethernet ports in M12 connector type. According to the link type, the
switch uses CAT 3, 4, 5,5e UTP cables to connect to any other network devices (PCs, servers,
switches, routers, or hubs). Please refer to the following table for cable specifications.