IDS-141A_181A Series
User’s Manual
ORing Industrial Networking Corp
44.
The following table describes the labels in this screen.
Label
Description
TCP Server Port
Set the port number for data transmission.
Idle Timeout
When serial port stops data transmission for a defined period of time (Idle Timeout), the
connection will be closed and the port will be freed and try to connect with other hosts. 0
indicate disable this function. Factory default value is 0. If Multilink is configured, only
the first host connection is effective for this setting.
Alive Check
The serial device will send TCP alive-check package in each defined time interval (Alive
Check) to remote host to check the TCP connection. If the TCP connection is not alive,
the connection will be closed and the port will be freed. 0 indicate disable this function.
Factory default is 0.
Max Connection
The number of Max connection can support simultaneous connections are 5, default values
is 1.
Table 5-17 TCP server mode